Application

These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.

Standards

  • BS 7917
  • IEC 60331-31 Fire resistant
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754-2 Corrosivity
  • IEC 61034-2 Smoke density
  • Cold bend and impact (-40°C) (on request)
  • CSA C22.2 No. 38-95 (on request)

BS 6883&BS7917 Offshore & Marine cables

Construction

  • Conductor: tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
  • Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.
  • Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

  • Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)
  • Temperature Range: -40℃ ~ +90℃

Dimensions and Weight

Single core cables

Construction No. of cores×Cross sectionNominal Insulation ThicknessNominal Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmkg/km
1×4116.7890
1×6117.28.5135
1×10118.19.5180
1×1611.19.310.7315
1×251.21.211.513.2550
1×351.21.212.314.1715
1×501.41.314.115.9830
1×701.41.315.817.81110
1×951.61.418.120.21470
1×1201.61.52022.42130
1×1501.81.62224.62475
1×18521.724.4272870
1×2402.21.827.530.33120
1×3002.41.930.433.64060

Multicore cables

Construction
No. of cores×Cross section
Nominal Insulation ThicknessNominal Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmkg/km
2×1.50.81.1910.4145
2×2.50.81.19.811.4180
2×411.211.813.5260
2×611.212.914.6325
2×1011.314.916.8445
2×1611.417.119.1630
2×251.21.521.223.7930
2×351.21.623.125.71210
2×501.41.726.529.21630
2×701.41.930.333.52210
2×951.62.134.938.23010
2×1201.62.238.442.23690
3×1.50.81.19.611170
3×2.50.81.110.412.1210
3×411.212.614.3310
3×611.213.815.5395
3×1011.315.917.8590
3×1611.418.220.3830
3×251.21.622.925.41270
3×351.21.724.927.61540
3×501.41.828.531.32100
3×701.4232.735.92870
3×951.62.237.5413910
3×1201.62.341.345.34800
3×1501.82.545.849.95810
3×18522.750.955.57290
3×2402.22.957.562.49440
4×1.50.81.110.512.1200
4×2.50.81.111.413.1250
4×411.213.815.6375
4×611.315.317.3495
4×1011.417.719.7740
4×1611.520.322.81050
4×251.21.725.528.11580
4×351.21.827.730.51960
4×501.41.931.8352570
4×701.42.136.339.73530
4×951.62.341.745.74850
4×1201.62.546.250.35990
5×1.50.81.111.413.1220
7×1.50.81.212.614.4285
12×1.50.81.316.818.8465
19×1.50.81.419.922.4680
27×1.50.81.624.326.9960
37×1.50.81.727.430.41260
5×2.50.81.212.714.4310
7×2.50.81.213.915.6375
12×2.50.81.418.720.8610
19×2.50.81.522.124.7895