Application

These fire-resistant medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.

Standards

  • BS 7917
  • IEC 60331-31 Fire resistant
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754-2 Corrosivity
  • IEC 61034-2 Smoke density
  • Cold bend and impact (-40°C) (on request)
  • CSA C22.2 No. 38-95 (on request)

BS 6883&BS7917 Offshore & Marine cables

Construction

  • Conductor: tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
  • Insulation: Mica tape + HF-EPR GP5 according to BS 7655 1.2.
  • Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.
  • Armour: Galvanized steel wire braid or tinned bronze wire braid (single core).
  • Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

  • Minimum Internal Bending Radius: 6×OD
  • Temperature Range: -40℃ ~ +90℃

Dimensions and Weight

1.9/3.3kV

Construction
No. of cores×Cross section
Nominal Insulation ThicknessNominal Inner Sheath ThicknessMinimum
Diameter
Over
Inner
Sheath
Maximum Diameter Over Inner SheathNominal Armour Wire DiameterNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmmmmmmmmmkg/km
1×252.21.213.415.20.31.417.519.9687
1×352.21.314.416.40.31.418.621806
1×502.21.315.617.60.31.52022.8983
1×702.21.417.619.60.31.622.1251283
1×952.41.519.822.30.31.724.527.61637
1×1202.41.621.724.20.31.726.429.51997
1×1502.41.623.225.80.451.828.8322439
1×1852.41.725.227.80.451.93134.72933
1×2402.41.827.930.70.45233.937.73671
1×3002.41.930.433.60.452.136.640.54446
1×4002.6234.137.50.452.340.745.25435
1×5002.82.23841.50.452.544.949.66746
1×6302.82.341.645.60.452.648.8548583
3×252.21.827.430.10.45233.437.22072
3×352.21.829.332.40.452.135.539.32422
3×502.21.932.135.30.452.238.442.82977
3×702.22.136.239.60.452.442.947.53920
3×952.42.34144.90.452.648.253.45041
3×1202.42.444.948.90.452.752.257.66165
3×1502.42.648.4530.452.956.261.77333
3×1852.42.752.557.20.45360.566.68800
3×2402.4358.563.80.453.36773.411172
3×3002.43.26469.40.453.572.879.913587

3.3/3.3kV

Construction
No. of cores×Cross section
Nominal Insulation ThicknessNominal Inner Sheath ThicknessMinimum
Diameter
Over
Inner
Sheath
Maximum Diameter Over Inner SheathNominal Armour Wire DiameterNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmmmmmmmmmkg/km
1×2531.315.117.10.31.519.422.3789
1×3531.316180.31.520.323.2900
1×5031.417.419.40.31.621.924.81097
1×7031.519.321.70.31.623.826.81392
1×9531.52123.50.31.725.728.81715
1×12031.622.925.40.31.827.830.92097
1×15031.724.527.20.451.930.3342568
1×18531.726.3290.45232.336.13050
1×24031.82932.20.452.135.239.13798
1×30031.931.634.80.452.237.941.94582
1×40032.135.138.50.452.341.746.25533
1×5003.22.238.742.60.452.545.750.46828
1×6303.22.443.646.60.452.649.7558712
3×2531.930.934.10.452.137.141.12358
3×35323336.20.452.239.443.82747
3×5032.135.839.10.452.342.346.93325
3×7032.239.743.50.452.546.651.44274
3×9532.443.747.70.452.751.156.45347
3×12032.547.551.70.452.855.160.66493
3×15032.751.155.70.4535965.17684
3×18532.855.2600.453.263.569.89213
3×24033.161.266.60.453.469.976.811583
3×30033.366.672.20.453.675.782.914031