Loading...

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Armoured Flame Retardant Instrumentation & Control Cables

Home/BS 6883&BS7917 Offshore & Marine Cables/150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Armoured Flame Retardant Instrumentation & Control Cables

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Armoured Flame Retardant Instrumentation & Control Cables

Application

These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits.

Standards

  • BS 6883
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754-2 Corrosivity
  • IEC 61034-2 Smoke density
  • Cold bend and impact (-40°C) (on request)
  • CSA C22.2 No. 38-95 (on request)

BS 6883&BS7917 Offshore & Marine cables

Construction

  • Conductor: tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
  • Insulation: HF-EPR GP4 according to BS 7655 1.2.
  • Lay-up: Pairs, triples.
  • Collective Screen: Aluminium/polyester tape + drain wire tinned copper.
  • Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.
  • Armour: Galvanized steel wire braid. Tinned bronze wire braid can be offered upon request.
  • Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

  • Minimum Internal Bending Radius: 8×OD
  • Temperature Range: -40℃ ~ +90℃

Dimensions and Weight

Construction No. of cores×Cross sectionNominal Insulation ThicknessNominal Inner Sheath ThicknessMinimum  Diameter Over Inner SheathMaximum Diameter Over Inner SheathNominal Armour Wire DiameterNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmmmmmmmmmkg/km
Multipair
3×2×0.750.81.212.614.50.31.416.719390
7×2×0.750.81.416.618.70.31.520.923.8620
12×2×0.750.81.621.724.20.31.726.429.5930
20×2×0.750.81.827.330.10.45233.337.11460
27×2×0.750.81.931.134.20.452.237.441.41810
37×2×0.750.82.134.437.70.452.34145.52270
3×2×10.81.213.315.30.31.417.419.8410
7×2×10.81.417.619.80.31.622.125.1680
12×2×10.81.623.125.70.31.82831.21010
20×2×10.81.82931.90.452.135.339.21600
27×2×10.8233.336.60.452.239.744.22000
37×2×10.82.236.940.30.452.443.748.32540
Multitriple
3×3×0.750.81.314.216.20.31.418.320.7480
7×3×0.750.81.419.421.90.31.62427780
12×3×0.750.81.724.226.80.451.929.332.91320
3×3×10.81.315.117.10.31.519.422.2530
7×3×10.81.520.923.40.31.725.628.7890
12×3×10.81.725.828.50.45231.835.51480
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.