huadong log
Loading...

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation & Control Cables

Home/BS 6883&BS7917 Offshore & Marine Cables/150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation & Control Cables

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation & Control Cables

Application

These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits.

Standards

  • BS 6883
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754-2 Corrosivity
  • IEC 61034-2 Smoke density
  • Cold bend and impact (-40°C) (on request)
  • CSA C22.2 No. 38-95 (on request)

Construction

  • Conductor: tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
  • Insulation: HF-EPR GP4 according to BS 7655 1.2.
  • Lay-up: Pairs, triples, quads.
  • Individual Screen: Aluminium/polyester tape + drain wire tinned copper.
  • Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.
  • Armour: Galvanized steel wire braid. Tinned bronze wire braid can be offered upon request.
  • Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

  • Minimum Internal Bending Radius: 8×OD
  • Temperature Range: -40℃ ~ +90℃

Dimensions and Weight

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum  Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
(mm²) mm mm mm mm mm mm mm mm kg/km
Multipair
1×2×0.75 0.8 1 7.3 9 0.3 1.2 11.1 12.9 250
3×2×0.75 0.8 1.2 12.6 14.5 0.3 1.4 16.7 19 440
7×2×0.75 0.8 1.4 16.9 19 0.3 1.6 21.4 24.3 730
12×2×0.75 0.8 1.6 21.3 23.7 0.3 1.8 26.1 29.2 1090
20×2×0.75 0.8 1.9 27 29.8 0.45 2.1 33.2 37 1750
27×2×0.75 0.8 2 30.8 33.9 0.45 2.3 37.3 41.3 2190
37×2×0.75 0.8 2.2 35.9 39.3 0.45 2.5 42.9 47.5 2780
1×2×1 0.8 1 7.7 9.5 0.3 1.2 11.5 13.4 260
3×2×1 0.8 1.3 13.5 15.5 0.3 1.4 17.6 20 490
7×2×1 0.8 1.4 18 20.1 0.3 1.6 22.5 25.4 810
12×2×1 0.8 1.7 22.8 25.4 0.45 1.9 28.6 31.8 1370
20×2×1 0.8 1.9 28.8 31.6 0.45 2.2 35.2 39 2010
27×2×1 0.8 2.1 32.8 36 0.45 2.4 39.5 44 2570
37×2×1 0.8 2.3 38.5 42.3 0.45 2.6 45.7 50.4 3290
Multitriple
1×3×0.75 0.8 1 7.7 9.4 0.3 1.2 11.5 13.3 270
3×3×0.75 0.8 1.3 14.2 16.2 0.3 1.5 18.6 20.9 540
7×3×0.75 0.8 1.5 19.7 22.1 0.3 1.7 24.4 27.4 910
12×3×0.75 0.8 1.7 24.4 27.1 0.45 2 30.4 34.1 1500
1×3×1 0.8 1.1 8.4 10.1 0.3 1.2 12.1 14 290
3×3×1 0.8 1.3 15 17.2 0.3 1.5 19.4 22.3 600
7×3×1 0.8 1.5 21 23.5 0.3 1.7 25.7 28.8 1030
12×3×1 0.8 1.8 26.2 28.9 0.45 2 32.2 36 1740
Multiquad
1×4×0.75 0.8 1.1 8.6 10.4 0.3 1.2 12.4 14.3 290
3×4×0.75 0.8 1.4 16.4 18.5 0.3 1.5 20.9 23.8 610
7×4×0.75 0.8 1.6 22.1 24.7 0.3 1.7 27 30.2 1060
1×4×1 0.8 1.1 9.1 10.9 0.3 1.2 12.9 14.8 330
3×4×1 0.8 1.4 17.5 19.6 0.3 1.6 22 24.9 680
7×4×1 0.8 1.6 23.6 26.2 0.45 1.8 29.4 32 1290
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!
There was an error trying to send your message. Please try again later.

MRE-M2X(St)CH 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened & Armoured Fire Resistant Instrumentation & Control Cables (Multipair/Multitriple)