Application

These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards

  • BS 6883
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754-2 Corrosivity
  • IEC 61034-2 Smoke density
  • Cold bend and impact (-40°C) (on request)
  • CSA C22.2 No. 38-95 (on request)

3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control Cables (Radial Field)

Construction

  • Conductor: tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
  • Conductor Screen: Semiconducting layer or tape.
  • Insulation: HF-EPR GP5 according to BS 7655 1.2.
  • Insulation Screen: Semiconducting layer or tape +tinned copper tape.
  • Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6

Mechanical and Thermal Properties

  • Minimum Internal Bending Radius: 15×OD (single core); 20×OD (three core)
  • Temperature Range: -40℃ ~ +90℃

Dimensions and Weight

3.8/6.6kV

Construction

No. of cores×Cross section

Nominal Insulation ThicknessNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmkg/km
1×1631.31618492
1×2531.317.619.7658
1×3531.418.720.8776
1×5031.419.922.3942
1×7031.521.824.31229
1×9531.623.726.31546
1×12031.625.4281890
1×15031.72729.82242
1×18531.82932.12713
1×24031.931.7353427
1×3003234.337.64177
1×40032.137.641.15145
1×5003.22.341.445.56408
1×6303.22.445.149.28134
3×1631.832.7361482
3×253236.539.92031
3×353238.441.92359
3×5032.241.345.32918
3×7032.345.349.43788
3×9532.549.353.94776
3×12032.653.157.85868
3×15032.756.561.46933
3×18532.960.866.18401
3×24033.166.672.210616

6.35/11kV

Construction No. of cores×Cross sectionNominal Insulation ThicknessNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmkg/km
1×163.41.316.818.8524
1×253.41.418.620.7704
1×353.41.419.421.9813
1×503.41.520.823.3994
1×703.41.522.625.11272
1×953.41.624.427.11592
1×1203.41.726.3291956
1×1503.41.727.830.62294
1×1853.41.829.832.92769
1×2403.41.932.535.83487
1×3003.423538.44242
1×4003.42.138.441.95208
1×5003.42.341.845.86442
1×6303.42.445.549.68176
3×163.41.934.537.91601
3×253.4238.241.62139
3×353.42.140.244.12497
3×503.42.243473040
3×703.42.447.151.33949
3×953.42.55155.64919
3×1203.42.75559.86055
3×1503.42.858.463.37132
3×1853.4362.768.18613
3×2403.43.268.574.110848

8.7/15kV

Construction No. of cores×Cross sectionNominal Insulation ThicknessNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmMmkg/km
1×254.51.520.923.4808
1×354.51.521.724.3921
1×504.51.522.925.51110
1×704.51.624.927.51396
1×954.51.726.729.51726
1×1204.51.828.631.42099
1×1504.51.830.133.32445
1×1854.51.932.135.32929
1×2404.5234.838.23661
1×3004.52.137.340.84429
1×4004.52.240.744.65390
1×5004.52.444.148.26638
1×6304.52.547.8528415
3×254.52.243.147.12458
3×354.52.345.249.22832
3×504.52.447.952.13395
3×704.52.652.156.74336
3×954.52.755.960.75334
3×1204.52.959.964.96500
3×1504.5363.368.77602
3×1854.53.267.673.29116