3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Radial Field)

Application

These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards

  • BS 6883
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754-2 Corrosivity
  • IEC 61034-2 Smoke density
  • Cold bend and impact (-40°C) (on request)
  • CSA C22.2 No. 38-95 (on request)

3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Radial Field)

Construction

  • Conductor: tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
  • Conductor Screen: Semiconducting layer or tape.
  • Insulation: HF-EPR GP5 according to BS 7655 1.2.
  • Insulation Screen: Semiconducting layer or tape +tinned copper tape.
  • Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.
  • Armour: Galvanized steel wire braid or tinned bronze wire braid (single core).
  • Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6

Mechanical and Thermal Properties

  • Minimum Internal Bending Radius: 15×OD (single core); 20×OD (three core)
    Temperature Range: -40℃ ~ +90℃

Dimensions and Weight

3.8/6.6kV

Construction No. of cores×Cross sectionNominal Insulation ThicknessNominal Inner Sheath ThicknessMinimum  Diameter Over Inner SheathMaximum Diameter Over Inner SheathNominal Armour Wire DiameterNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmmmmmmmmmkg/km
1×1631.316180.31.420.223790
1×2531.317.619.70.31.521.924.9950
1×3531.418.720.80.31.523261060
1×5031.419.922.30.31.624.427.41320
1×7031.521.824.30.31.726.529.61610
1×9531.623.726.30.31.828.631.81930
1×12031.625.4280.31.830.233.92260
1×15031.72729.80.451.932.836.62760
1×18531.82932.10.4523538.93210
1×24031.931.7350.452.137.941.93960
1×3003234.337.60.452.240.645.14660
1×40032.137.641.40.452.444.4495470
1×5003.22.341.445.40.452.548.453.66610
1×6303.22.445.149.20.452.752.457.88230
3×1631.832.7360.452.138.943.32610
3×253236.539.90.452.242.947.53220
3×353238.441.90.452.344.949.63700
3×5032.241.345.30.452.448.153.34360
3×7032.345.349.40.452.652.457.45410
3×9532.549.353.90.452.856.862.46710
3×12032.653.157.80.452.960.8677770
3×15032.756.661.40.453.164.670.99160
3×18532.960.866.10.453.269.17610430
3×24033.166.672.20.453.575.582.612840

6.35/11kV

Construction No. of cores×Cross sectionNominal Insulation ThicknessNominal Inner Sheath ThicknessMinimum  Diameter Over Inner SheathMaximum Diameter Over Inner SheathNominal Armour Wire DiameterNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmmmmmmmmmkg/km
1×163.41.316.818.80.31.521.124810
1×253.41.418.620.70.31.522.925.9980
1×353.41.419.421.90.31.624271110
1×503.41.520.823.30.31.625.328.41360
1×703.41.522.625.10.31.727.330.41660
1×953.41.624.427.10.31.829.3331970
1×1203.41.726.3290.451.932.135.92360
1×1503.41.727.830.60.45233.837.62810
1×1853.41.829.832.90.45235.839.73260
1×2403.41.932.535.80.452.238.943.34020
1×3003.423538.40.452.341.646.14760
1×4003.42.138.441.90.452.445.149.85610
1×5003.42.341.845.80.452.548.8546820
1×6303.42.445.549.60.452.752.858.28480
3×163.41.934.537.90.452.140.745.22660
3×253.4238.241.60.452.344.749.43310
3×353.42.140.244.10.452.44751.73960
3×503.42.243470.452.55055.24570
3×703.42.447.151.30.452.754.459.95610
3×953.42.55155.60.452.858.564.56820
3×1203.42.75559.80.45362.969.18070
3×1503.42.858.463.30.453.166.572.89260
3×1853.4362.768.10.453.371.278.110960
3×2403.43.268.574.10.453.677.585.213390

8.7/15kV

Construction No. of cores×Cross sectionNominal Insulation ThicknessNominal Inner Sheath ThicknessMinimum  Diameter Over Inner SheathMaximum Diameter Over Inner SheathNominal Armour Wire DiameterNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmmmmmmmmmkg/km
1×254.51.520.923.40.31.625.428.51150
1×354.51.521.724.30.31.726.429.61260
1×504.51.522.925.50.31.727.630.81510
1×704.51.624.927.50.31.829.833.41770
1×954.51.726.729.50.451.932.636.32270
1×1204.51.828.631.40.45234.638.52730
1×1504.51.830.133.30.452.136.340.23020
1×1854.51.932.135.30.452.138.342.33490
1×2404.5234.838.20.452.241.245.74260
1×3004.52.137.340.80.452.444.148.74810
1×4004.52.240.744.60.452.547.652.46160
1×5004.52.444.148.20.452.651.356.67330
1×6304.52.547.8520.452.855.360.88800
3×254.52.243.147.10.452.550.155.43610
3×354.52.345.249.20.452.652.357.74510
3×504.52.447.952.10.452.755.360.85210
3×704.52.652.156.70.452.959.865.96390
3×954.52.755.960.70.45363.870.17660
3×1204.52.959.964.90.453.268.275.18810
3×1504.5363.368.70.453.371.878.810070
3×1854.53.267.673.20.453.576.583.711420