3.8/6.6kV, 6.6/6.6kV, 6.35/11kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Non Radial Field)

Home/BS 6883&BS7917 Offshore & Marine Cables/3.8/6.6kV, 6.6/6.6kV, 6.35/11kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Non Radial Field)

3.8/6.6kV, 6.6/6.6kV, 6.35/11kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Non Radial Field)

Application

These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards

  • BS 6883
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754- 2 Corrosivity
  • IEC 61034-2 Smoke density
  • Cold bend and impact (-40°C) (on request)
  • CSA C22.2 No. 38-95 (on request)

BS 6883&BS7917 Offshore & Marine cables

Construction

  • Conductor: tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
  • Conductor Screen: Semiconducting layer or tape.
  • Insulation: HF-EPR GP5 according to BS 7655 1.2.
  • Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.
  • Armour: Galvanized steel wire braid or tinned bronze wire braid (single core).
  • Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6

Mechanical and Thermal Properties

  • Minimum Internal Bending Radius: 12×OD
  • Temperature Range: -40℃ ~ +90℃

Dimensions and Weight

3.8/6.6kV

Construction
No. of cores×Cross section
Nominal Insulation ThicknessNominal Inner Sheath ThicknessMinimum  Diameter Over Inner SheathMaximum Diameter Over Inner SheathNominal Armour Wire DiameterNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmmmmmmmmmkg/km
1×163.41.313.915.70.31.41820.4703
1×253.41.315.517.50.31.519.822.7899
1×353.41.416.618.60.31.520.923.81029
1×503.41.417.819.80.31.622.325.21223
1×703.41.519.722.10.31.724.427.41547
1×953.41.621.624.10.31.826.529.61903
1×1203.41.623.225.80.31.828.131.32266
1×1503.41.724.927.60.451.930.734.42760
1×1853.41.826.929.60.45232.936.73282
1×2403.41.929.632.80.452.135.839.74059
1×3003.4232.135.40.452.238.542.94872
1×4003.42.135.538.90.452.442.246.85844
1×5003.42.238.742.60.452.545.750.47113
1×6303.42.442.646.60.452.749.955.29093
3×163.41.828.130.90.452.134.338.22109
3×253.4231.935.20.452.238.342.32747
3×353.4233.837.10.452.340.444.93133
3×503.42.236.840.20.452.443.548.23772
3×703.42.340.744.60.452.647.952.74771
3×953.42.544.748.80.452.852.357.75900
3×1203.42.648.653.10.452.956.361.87098
3×1503.42.751.956.60.453.160.166.28304
3×1853.42.956.261.10.453.264.670.89895
3×2403.43.16267.40.453.570.977.912358

6.6/6.6kV

Construction
No. of cores×Cross section
Nominal Insulation ThicknessNominal Inner Sheath ThicknessMinimum  Diameter Over Inner SheathMaximum Diameter Over Inner SheathNominal Armour Wire DiameterNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmmmmmmmmmkg/km
1×255.51.519.922.40.31.724.627.71211
1×355.51.520.823.30.31.725.528.61338
1×505.51.622.224.70.31.827.130.21565
1×705.51.724.126.70.451.929.933.62017
1×955.51.725.828.50.45231.835.52383
1×1205.51.827.730.40.45233.737.52794
1×1505.51.929.332.50.452.135.539.43213
1×1855.51.931.134.30.452.237.541.53737
1×2405.5233.837.20.452.340.444.94548
1×3005.52.136.439.80.452.443.147.75392
1×4005.52.339.943.80.452.64751.86384
1×5005.52.443.247.20.452.750.555.87689
1×6305.52.546.8510.452.854.359.89709
3×255.52.341.245.10.452.648.453.63746
3×355.52.443.347.30.452.750.655.94204
3×505.52.546.150.20.452.853.6594872
3×705.52.750.254.80.45358.164.15992
3×955.52.85458.80.453.162.168.37130
3×1205.5358630.453.366.572.98486
3×1505.53.161.466.80.453.470.1779723
3×1855.53.365.771.30.453.674.881.911448
3×2405.53.571.577.60.453.981.28914038
3×1853.42.956.261.10.453.264.670.89895

6.35/11kV

Construction
No. of cores×Cross section
Nominal Insulation ThicknessNominal Inner Sheath ThicknessMinimum

Diameter

Over

Inner

Sheath

Maximum Diameter Over Inner SheathNominal Armour Wire DiameterNominal Outer Sheath ThicknessMinimum Overall DiameterMaximum Overall DiameterApprox. Weight
(mm²)mmmmmmmmmmmmmmmmkg/km
1×356.51.622.925.50.31.827.8311514
1×506.51.724.326.90.451.930.133.81751
1×706.51.72628.70.4523235.82201
1×956.51.827.930.70.452.134.137.92600
1×1206.51.929.832.90.452.13639.93021
1×1506.51.931.234.50.452.237.641.63427
1×1856.5233.336.50.452.339.844.33987
1×2406.52.13639.40.452.442.747.34814
1×3006.52.238.542.30.452.545.450.15674
1×4006.52.442460.452.649.254.46637
1×5006.52.545.349.40.452.852.858.27986
1×6306.52.648.953.50.452.956.662.210057
3×356.52.647.8520.452.955.561.14793
3×506.52.750.655.20.45358.564.65489
3×706.52.854.559.30.453.262.8696612
3×956.5358.663.50.453.36773.47829
3×1206.53.162.467.80.453.571.378.29182
3×1506.53.36671.50.453.67582.210498
3×1856.53.470.176.10.453.879.587.212218