P30 RFOU-HCF / TFOU-HCF 6/10(12) kV cables

Home/NEK 606 Offshore & Marine Cables/P30 RFOU-HCF / TFOU-HCF 6/10(12) kV cables

P30 RFOU-HCF / TFOU-HCF 6/10(12) kV cables  Applications

P30 RFOU-HCF / TFOU-HCF 6/10(12) kV cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency control, power and lighting systems that need to be operational during a 1100℃ hydrocarbon fire.

P30 RFOU-HCF / TFOU-HCF 6/10(12) kV cables  Standards

IEC 60092-354IEC 60092-351
IEC 60092-359IEC 60332-1
IEC 60331-21IEC 60332-3-22
IEC 60754-1,2IEC 61034-1,2
NEK 606:2004

 

P30 RFOU-HCF / TFOU-HCF 6/10(12) kVP30 RFOU-HCF / TFOU-HCF 6/10(12) kV

P30 RFOU-HCF / TFOU-HCF 6/10(12) kV cables  Construction

  • Conductors : Circular tinned annealed stranded copper to IEC 60228 class 2.
  • Conductor Screen : Semi conducting material.
  • Insulation : Halogen-free EPR. XLPE can be offered as an option.
  • Insulation Screen : Semi conducting material and tinned copper wire braid.
  • Bedding : Halogen free compound.
  • Armour : Tinned copper wire braid.
  • Outer Sheath1 : Halogen free thermosetting compound, SHF2, coloured red.
  • HC-fire protection : Extruded thermoplastic fire protection compound.
  • Taping : Lapped glass fibre tape.
  • Outer Sheath2 : Flame retardant halogen-free thermoplastic compound, SHF1, coloured red.

Optional

  • P31 RFOU-HCF / TFOU-HCF 8.7/15kV
  • P32 RFOU-HCF / TFOU-HCF 12/20(24) kV
  • P33 RFOU-HCF / TFOU-HCF 18/30(36) kV

P30 RFOU-HCF / TFOU-HCF 6/10(12) kV cables  Electrical Characteristics

Nominal Cross Section Areamm²7095120150185240300
Nominal Conductor Diametermm10.312.213.815.117.019.621.9
Maximum DC Resistant@20℃Ω/km0.270.1950.1540.1260.10.07620.0607
Continuous Current Rating@45℃1 CoreA242293339389444522601
Continuous Current Rating@45℃3 CoreA169205237272311365421
Short Circuit Current 1sA10020135901717021460264703434042930
Operating VoltageKV6/106/106/106/106/106/106/10

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors35404550556065707580
Rating Factor1.11.051.00.940.880.820.740.670.580.47

Mechanical and Thermal Properties

  • Bending Radius : 25×OD (during installation); 12×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

P30 RFOU-HCF / TFOU-HCF 6/10(12) kV cables  Dimensions and Weight

Construction No. of cores×Cross section
(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over Bedding
mm
Nominal Diameter Over Sheath1
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
1×703.423.530.062.05220
1×953.425.532.064.55900
1×1203.427.534.066.56340
1×1503.428.535.067.56670
1×1853.430.536.569.07320
1×2403.433.039.072.08250
1×3003.435.041.574.59280
3×503.447.055.089.010970
3×953.454.062.597.014230
3×1503.460.070.5106.017400

 