Loading...

250V [FA-] TTY-S, TTYC-S, TTYCY-S [FA-] TTPY-S, TTPYC-S, TTPYCY-S

Home/JIS C 3410 Shipboard cables/250V [FA-] TTY-S, TTYC-S, TTYCY-S [FA-] TTPY-S, TTPYC-S, TTPYCY-S

250V[FA-] TTY-S, TTYC-S, TTYCY-S[FA-] TTPY-S, TTPYC-S, TTPYCY-S

Standards

  • JISC 3410-1999
  • IEC 60332-1
  • IEC 60332-3 Cat.A(for FA-type)

Cable Construction

TTY-S, TTYC-S, TTYCY-S

ConductorTT
TTP
Tinned annealed stranded copper (TTY-type) Tinned annealed stranded
copper (TTPY-type), class 2 according to IEC 60228
Insulation60°C PVC(TTY-type)/ 85°C EPR(TTPY-type) as per JIS C 3410
TwistingTwo Insulated cores shall be twisted together to form a pair
Individual shield-STinned copper wire braid
CablingTwisted pairs shall be cabled.
Flame retardant & non-hygroscopic fillers may be used
BeddingYPVC as per JIS C 3410
ArmorCGalvanized steel wire braid
SheathYPVC as per JIS C 3410
Core identificationPrinted pair number and Alphabet letter on the white insulation.
ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
– 1T, 1Q cable shall be identified by the black number on the white insulation
Outer sheath colorBlack

Cable Parameter

(FA-) TTY-S,TTPY-S

No. of
pair, Triad or
Quad
ConductorThick. of
insulation
Dia. of
shield
wire
Thick. of
bedding
(FA-) TTY-S,TTPY-S
SizeConstructionO.DNom.
overall dia
ToleranceCable
Weight
mm²No./mmmmmmmmmmmmmmkg/km
20.757/0.371.10.70.141.314.40.6200
40.757/0.371.10.70.141.417.40.7370
70.757/0.371.10.70.141.520.90.9550
100.757/0.371.10.70.141.827.41.1880
140.757/0.371.10.70.141.829.81.21190
190.757/0.371.10.70.14233.61.41470
240.757/0.371.10.70.142.239.81.61930
300.757/0.371.10.70.142.342.41.72280
370.757/0.371.10.70.142.4461.82740
480.757/0.371.10.70.142.753.31.93590

(FA-) TTYC-S,TTPYC-S

No. of pair, Triad or QuadConductorThick. of insulationDia. of shield wireThick. of beddingDia. of steel wire(FA-) TTYC-S,TTPYC-S
SizeConstructionO.DNom.overall diaToleranceCable Weight
mm²No./mmmmmmmmmmmmmmmmkg/km
20.757/0.371.10.70.141.30.3160.7320
40.757/0.371.10.70.141.40.318.70.7490
70.757/0.371.10.70.141.50.322.20.9690
100.757/0.371.10.70.141.80.328.71.11070
140.757/0.371.10.70.141.80.331.11.21400
190.757/0.371.10.70.1420.435.41.41780
240.757/0.371.10.70.142.20.441.61.62300
300.757/0.371.10.70.142.30.444.21.72680
370.757/0.371.10.70.142.40.447.81.83170
480.757/0.371.10.70.142.70.455.11.94090

(FA-) TTYCY-S,TTPYCY-S

No. of
pair, Triad or
Quad
ConductorThick. of
insulation
Dia. of
shield
wire
Thick. of
bedding
Dia. of
steel wire
Thick. of
covering
(FA-)TTYCY-S,TTPYCY-S
SizeConstructionO.DNom.
overall dia
ToleranceCable
Weight
mm²No./mmmmmmmmmmmmmmmmmmkg/km
20.757/0.371.10.70.141.30.3118.10.8375
40.757/0.371.10.70.141.40.31.121.10.8595
70.757/0.371.10.70.141.50.31.224.81825
100.757/0.371.10.70.141.80.31.331.51.31250
140.757/0.371.10.70.141.80.31.434.11.41610
190.757/0.371.10.70.1420.41.538.81.62050
240.757/0.371.10.70.142.20.41.645.21.72640
300.757/0.371.10.70.142.30.41.7481.83060
370.757/0.371.10.70.142.40.41.851.81.93600
480.757/0.371.10.70.142.70.4259.524630