Loading...

Armoured Cat 5e SF/UTP 24AWG

Home/IEC60092 Offshore & Marine Cables/Armoured Cat 5e SF/UTP 24AWG

Armoured Cat 5e SF/UTP 24AWG

Application

These Cat5e SF/UTP cables are manufactured in accordance with IEC 61156-5 requirements, can support all Class D applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for basic voice and data installations up to 100MHz.

Standards

  • EN 50288
  • ISO 11801
  • IEC 61156-5
  • IEC 60332-1
  • IEC 60754-1/2
  • IEC 61034

Construction

Armoured Cat 5e SF/UTP 24AWG

  • Conductors: Bare copper conductor.
  • Insulation: PE.
  • Twinning: Two coloured insulated conductors twisted together to form a pair.
  • Overall Screen1: Al/polyester tape.
  • Overall Screen2: Tinned copper wire braid.
  • Inner Sheath: LSOH.
  • Armour: Tinned copper wire braid.
  • Outer Sheath: LSOH (SHF1).

Core Identification

  • Pair 1: White/Blue, Blue
  • Pair 2: White/Orange, Orange
  • Pair 3: White/Green, Green
  • Pair 4: White/Brown, Brown

Electrical Properties

Characteristic Impedance(1-100MHz)Ω100±15
Nominal Velocity of Propagation(NVP)69%
Maximum Mutual CapacitancenF/100m5.6
Maximum Capacitance UnbalancepF/100m330
Maximum Resistance Unbalance5%
Maximum Propagation Delay Skewns/100m30
Maximum Propagation Delay@100MHzns/100m536
Voltage RatingV rms80

Nominal Transmission Characteristics @20℃

FREQNEXTAttenuationRLACRELFEXTPSNEXTPSACRPSELFEXT
MHzdB/100mdB/100mdB/100mdB/100mdB/100mdB/100mdB/100mdB/100m
165.3220.263.363.862.360.360.8
456.34.12352.251.753.349.248.7
851.85.824.54645.748.84342.7
1050.36.52543.843.847.340.840.8
1647.38.22539.139.744.336.136.7
2045.89.32536.537.742.833.534.7
2544.310.424.333.935.841.330.932.8
31.2542.911.723.631.233.939.928.230.9
62.538.41721.521.427.835.418.424.8
10035.32220.113.323.832.310.320.8
15532.528.118.84.419.929.5-1.416.9
20030.732.418-1.718.727.7-4.715.7
31029.341.817.3N/A1026.3N/A13
35027.144.917.3N A7.124.1N A10.1

* Data for 100MHz above are for reference only

Mechanical and Thermal Properties

  • Bending Radius: 8×OD (during installation); 4×OD (fixed installed)
  • Temperature Range: -20℃ ~ +60℃

Dimensions and Weight

Part No.Construction No. of elements×No. of cores in element×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmNominal Overall Diameter mmNominal Weight kg/km
InnerOuter
MLN-SF/UTPCAT5EA4P244×2×24AWG0.250.741.2210.5173
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.