Breakout Fiber Cable

Application

These optical fiber cables are designed to data transmission in ship and specially in cruise ship where low smoke, halogen free and flame retardant cables are required to increase safety on board, suitable for flexible installation on and below deck of commercial ships without constant exposure to oil, grease and other lubricants.

Standards

  • IEC 60092-350/351/352/353/359/370
    /376
  • IEC 60332-1-2
  • IEC 60332-3-22
  • IEC 60754-1/2
  • IEC 61034

Construction

Breakout Fiber Cable

  • Optical Fiber: Semi tight buffered.
  • Strain Relief Elements: Aramid.
  • Subcable Sheath: Halogen-free, flame-retardant compound.
  • Central Strength Member
  • Separator: Taping.
  • Strain Relief Elements: Aramid.
  • Outer Sheath: SHF1.

Fiber Specification

G50/125 G62.5/125 E9/125
Geometry/Mechanical Properties
Core Diameter µm 50 ± 2.5 62.5 ± 3
Mode Field Diameter (at 1310 nm) µm 9.2 ± 0.4
Cladding Diameter µm 125 ± 2 125 ± 1 125 ± 2
Coating Diameter µm 245 ± 10 245 ± 5 245 ± 10
Core Non-circularity % < 5 < 5
Cladding Non-circularity % < 1 < 1 < 1
Core/Clad Concentricity Error µm < 1.5 < 1.5 < 0.8
Eccentricity of Coating µm < 10 < 10 < 10
Screen Test ≥100 kpsi ≥100 kpsi ≥100 kpsi
Transmission Properties OM2 OM1 OS1
Wavelength nm 850 1300 850 1300 1310 1550
Attenuation Max. dB/km 2.7 0.8 3.2 0.9 0.36 0.22
Bandwidth Min. MHz. km 500 1000 250 600
Effective Group of Refraction 1.483 1.478 1.497 1.493 1.4695 1.4701
Numerical Aperture 0.200 ± 0.015 0.275 ± 0.015
Dispersion Coefficient Max. ps/nm.km 3.5 18
Zero Dispersion Wavelength nm 1300
–1322
Dispersion Slope ps/nm² .km ≤0.092
Cutoff Wavelength (cabled) nm ≤1250
Polarization Mode Dispersion ps/km1/2 ≤0.1

Mechanical and Thermal Properties

  • Bending Radius for Fixed Installations: 15×OD
  • Temperature Range: -20℃ ~ +80℃

Dimensions and Weight

Part No. No. of Optical Fibers Nominal Overall Diameter mm Nominal Weight kg/km
MLN-BTA-X-2-H-F-H-CD-A 2 10.1 85
MLN-BTA-X-4-H-F-H-CD-A 4 10.1 85
MLN-BTA-X-6-H-F-H-CD-A 6 11.8 120
MLN-BTA-X-8-H-F-H-CD-A 8 13.6 160
MLN-BTA-X-10-H-F-H-CD-A 10 15.4 200
MLN-BTA-X-12-H-F-H-CD-A 12 17.2 245

Note: X: Fiber type (0=Fiber and copper conductors in cable 4=50/125 multi-mode fiber
(OM3); 5=50/125 multi-mode fiber (OM2); 6=50/125 multi-mode fiber (OM1); 7=NZDS SM
fiber per G.656.; 8=NZDS SM fiber per G.655.; 9=Standard SM fiber per G.652.D)

For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!
There was an error trying to send your message. Please try again later.

MRE-2X(St)HCH 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened & Armoured Flame RetardantInstrumentation & Control Cables (Multipair/Multitriple)

Go to Top