Loading...

Breakout Fiber Cable

Breakout Fiber Cable

Application

These optical fiber cables are designed to data transmission in ship and specially in cruise ship where low smoke, halogen free and flame retardant cables are required to increase safety on board, suitable for flexible installation on and below deck of commercial ships without constant exposure to oil, grease and other lubricants.

Standards

  • IEC 60092-350/351/352/353/359/370
    /376
  • IEC 60332-1-2
  • IEC 60332-3-22
  • IEC 60754-1/2
  • IEC 61034

Construction

Breakout Fiber Cable

  • Optical Fiber: Semi tight buffered.
  • Strain Relief Elements: Aramid.
  • Subcable Sheath: Halogen-free, flame-retardant compound.
  • Central Strength Member
  • Separator: Taping.
  • Strain Relief Elements: Aramid.
  • Outer Sheath: SHF1.

Fiber Specification

G50/125G62.5/125E9/125
Geometry/Mechanical Properties
Core Diameterµm50 ± 2.562.5 ± 3
Mode Field Diameter (at 1310 nm)µm9.2 ± 0.4
Cladding Diameterµm125 ± 2125 ± 1125 ± 2
Coating Diameterµm245 ± 10245 ± 5245 ± 10
Core Non-circularity%< 5< 5
Cladding Non-circularity%< 1< 1< 1
Core/Clad Concentricity Errorµm< 1.5< 1.5< 0.8
Eccentricity of Coatingµm< 10< 10< 10
Screen Test≥100 kpsi≥100 kpsi≥100 kpsi
Transmission PropertiesOM2OM1OS1
Wavelengthnm8501300850130013101550
Attenuation Max.dB/km2.70.83.20.90.360.22
Bandwidth Min.MHz. km5001000250600
Effective Group of Refraction1.4831.4781.4971.4931.46951.4701
Numerical Aperture0.200 ± 0.0150.275 ± 0.015
Dispersion Coefficient Max.ps/nm.km3.518
Zero Dispersion Wavelengthnm1300
–1322
Dispersion Slopeps/nm² .km≤0.092
Cutoff Wavelength (cabled)nm≤1250
Polarization Mode Dispersionps/km1/2≤0.1

Mechanical and Thermal Properties

  • Bending Radius for Fixed Installations: 15×OD
  • Temperature Range: -20℃ ~ +80℃

Dimensions and Weight

Part No.No. of Optical FibersNominal Overall Diameter mmNominal Weight kg/km
MLN-BTA-X-2-H-F-H-CD-A210.185
MLN-BTA-X-4-H-F-H-CD-A410.185
MLN-BTA-X-6-H-F-H-CD-A611.8120
MLN-BTA-X-8-H-F-H-CD-A813.6160
MLN-BTA-X-10-H-F-H-CD-A1015.4200
MLN-BTA-X-12-H-F-H-CD-A1217.2245

Note: X: Fiber type (0=Fiber and copper conductors in cable 4=50/125 multi-mode fiber
(OM3); 5=50/125 multi-mode fiber (OM2); 6=50/125 multi-mode fiber (OM1); 7=NZDS SM
fiber per G.656.; 8=NZDS SM fiber per G.655.; 9=Standard SM fiber per G.652.D)

For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!
There was an error trying to send your message. Please try again later.

MRE-M2X(St)H 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened Fire Resistant Instrumentation & Control Cables(Multipair/Multitriple)

Go to Top