Loading...

EPR Insulated AC Medium-voltage Submarine Cable

Home/Submarine Cables/EPR Insulated AC Medium-voltage Submarine Cable

EPR Insulated AC Medium-voltage Submarine Cable

Applications

These submarine cables are used for power transmission to offshore islands, oil platforms or to cross-rivers and lakes. Cable design based on the mayor national or international standards e.g. VDE, IEC and ICEA or according to customers design and standards.

Construction

Submarine Cables

  • Conductor:Copper conductor, circular stranded compacted, water blocked.
  • Conductor Screening: Extruded semi-conductive compound.
  • Insulation: EPR.
  • Insulation Screening: Extruded semi-conductive compound.
  • Screen: Copper tapes.
  • Fillers: Polypropylene filler.
  • Separator: Binder tapes
  • Bedding Layer: Polypropylene strings.
  • Armour: Galvanized steel wires.
  • Serving: Hessian tapes, bituminous compound, polypropylene strings.

Electrical Data:

6/10(12) kV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm²μF/mmmH/kmA
350.270.37166
500.300.35197
700.340.33242
950.380.32289
1200.420.31328
1500.450.30367
1850.490.29402
2400.550.28469

12/20(24) kV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm²μF/mmmH/kmA
350.190.41166
500.210.39197
700.240.37241
950.260.35288
1200.290.34327
1500.310.33365
1850.330.32409
2400.370.31470

18/30(36) kV

Nominal Cross Section AreaCapacitanceInductanceCurrent Rating
mm²μF/mmmH/kmA
500.170.43196
700.180.41241
950.200.39287
1200.220.37325
1500.230.36364
1850.250.35406
2400.280.33467

Dimension and Weight:

6/10(12) kV

Nominal
Cross
Section Area
Nominal
Conductor
Diameter
Nominal
Insulation
Thickness
Nominal
Screen Cross
Section Area
Nominal
Bedding
Thickness
Nominal
Steel Wire
Diameter
Serving
Thickness
Overall
Diameter
Weight
mm²mmmmmm²mmmmmmmmkg/m
357.03.43×42.03.153.5565.4
508.23.43×42.03.153.5595.9
709.93.43×5.42.04.03.5647.9
9511.53.43×5.42.04.03.5689.1
12013.03.43×5.42.04.03.57110.2
15014.53.43×62.04.03.57411.4
18516.13.43×62.55.04.08615.0
24018.63.43×62.55.04.08716.7

12/20(24) kV

Nominal
Cross
Section Area
Nominal
Conductor
Diameter
Nominal
Insulation
Thickness
Nominal
Screen Cross
Section Area
Nominal
Bedding
Thickness
Nominal
Steel Wire
Diameter
Serving
Thickness
Overall
Diameter
Weight
mm²mmmmmm²mmmmmmmmkg/m
357.05.53×623.153.5656.8
508.25.53×623.153.5687.4
709.95.53×624.03.5739.5
9511.55.53×624.03.57710.7
12013.05.53×624.03.58011.8
15014.55.53×624.03.58313.0
18516.15.53×825.04.09016.2
24018.65.53×825.04.09518.5

18/30(36) kV

Nominal
Cross
Section Area
Nominal
Conductor
Diameter
Nominal
Insulation
Thickness
Nominal
Screen Cross
Section Area
Nominal
Bedding
Thickness
Nominal
Steel Wire
Diameter
Serving
Thickness
Overall
Diameter
Weight
mm²mmmmmm²mmmmmmmmkg/m
508.28.03×623.153.5799.2
709.98.03×624.03.58411.5
9511.58.03×824.03.58812.8
12013.08.03×824.03.59114.0
15014.58.03×824.03.59415.4
18516.18.03×1025.04.010118.7
24018.68.03×1025.04.010621.1
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.