F1 QFCI Applications

These steel armoured optical fibre cables are flame retardant, low smoke, halogen-free and fire-resistant, used for communication and emergency systems that need to be operational during fire.

F1 QFCI Standards

IEC 60794 IEC 60811-2-1
IIEC 60331-25 IEC 60332-3-24
IEC 60332-3-22 IEC 60754-1,2
IEC 61034-1,2 NEK 606:2004
F1 QFCI F1 QFCI

F1 QFCI Construction

  • Fibre Element : Loose tube core design.
  • Central Strength Element : Steel wire or fibre reinforced plastic (FRP).
  • Bedding : Halogen free and flame retardant thermoplastic compound.
  • Armour : Galvanized steel wire braid.
  • Outer Sheath : Halogen free and flame retardant, UV-stabilized, thermoplastic compound, SHF1.

Optional :

F4 QFCI-HCF : QFCI-HCF cables are consist of loose tube fiber element, steel wire or FRP central strength element, halogen-free and flame retardant thermoplastic bedding, galvanized steel wire braid armour, SHF1 sheath, HC-fire protection, fire-resistant tape and SHF1 outer sheath.

F1 QFCI Electrical Characteristics

Fibre Type 9/125 50/125 50/125 62.5/125
ITU-T type G652.D G651 G651
IEC11801 Classification OS1 & OS2 OM2 OM3 OM1
Core Diameter μm 8.7±0.4 50±3.0 50±3.0 62.5±3.0
Cladding Diameter μm 125 ±1.0 125 ±2.0 125 ±2.0 125 ±2.0
Coating Diameter μm 245 ±10 245 ±10 245 ±10 245 ±10
Maximum Attenuation
@850 nm dB/km 3.0 3.0 3.5
@1300 nm dB/km 1.5 1.0 1.5
@1310 nm dB/km 0.36
@1550 nm dB/km 0.22
Minimum Bandwidth(OFL*)
@850 nm MHz.km 500 1500 200
@1300 nm MHz.km 500 500 600
Maximum Chromatic Dispersion
1285-1330 nm ps/nm⋅km 2.8
1550 nm ps/nm⋅km 18
Zero Dis ersion Wavelen th nm 1300~1324

Mechanical and Thermal Properties

  • Bending Radius : 20×OD (during installation); 10×OD (fixed installed).
  • Temperature Range : -40℃ ~ +70℃.

F1 QFCI Dimensions and Weight

No. of Fibres Construction No. of tubes×No. of fibres in each tube Number of Fillers Nominal Loose Tube Diameter
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
2 1×2 5 2.2 13.9 244
4 1×4 5 2.2 13.9 244
6 3×2 3 2.2 13.9 244
8 2×4 4 2.2 13.9 244
10 5×2 1 2.2 13.9 244
12 3×4 3 2.2 13.9 244
16 4×4 2 2.2 13.9 244
20 5×4 1 2.2 13.9 244
24 6×4 0 2.2 13.9 244
32 4×8 2 2.2 13.9 244
40 5×8 1 2.2 13.9 244
48 6×8 0 2.2 13.9 244
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!
There was an error trying to send your message. Please try again later.

MRE-M2X(St)H 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened Fire Resistant Instrumentation & Control Cables(Multipair/Multitriple)

MRE-2XCH PiMF/TiMF 150/250V XLPE Insulated, LSOH (SHF1)Sheathed, Individual Screened & Armoured Flame RetardantInstrumentation & Control Cables (Multipair/Multitriple)

Go to Top