huadong log
Loading...

[FA-] TTY, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCY

Home/JIS C 3410 Shipboard cables/[FA-] TTY, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCY

[FA-] TTY, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCY

Standards

  • JISC 3410-1999
  • IEC 60332-1
  • IEC 60332-3 Cat.A(for FA-type)

Cable Construction

[FA-] TTY,TTYC,TTYCY

Conductor TT
TTP
Tinned annealed stranded copper (TTY-type) Tinned annealed stranded
copper (TTPY-type), class 2 according to IEC 60228
Insulation 60°C PVC(TTY-type)/ 85°C EPR(TTPY-type) as per JIS C 3410
Twisting Two Insulated cores shall be twisted together to form a pair
Cabling Twisted pairs shall be cabled.
Flame retardant & non-hygroscopic fillers may be used
Bedding Y PVC as per JIS C 3410
Armor C Galvanized steel wire braid
Sheath Y PVC as per JIS C 3410
Core identification Printed pair number and Alphabet letter on the white insulation.
ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
– 1T, 1Q cable shall be identified by the black number on the white
insulation
Outer sheath color Black

Cable Parameter

(FA-) TTY,TTPY

No. of pair, Triad or Quad Conductor Thick. of insulation Thick. of bedding (FA-) TTY,TTPY
Size Construction O.D Nom.overall dia Tolerance Cable Weight
mm² No./mm mm mm mm mm mm kg/km
1 0.75 7/0.37 1.1 0.7 1 7.9 0.4 70
1T 0.75 7/0.37 1.1 0.7 1.1 8.6 0.4 85
1Q 0.75 7/0.37 1.1 0.7 1.1 9.3 0.4 105
2 0.75 7/0.37 1.1 0.7 1.2 12 0.6 105
4 0.75 7/0.37 1.1 0.7 1.3 14.2 0.6 205
7 0.75 7/0.37 1.1 0.7 1.4 16.9 0.7 310
10 0.75 7/0.37 1.1 0.7 1.5 21.7 0.9 465
14 0.75 7/0.37 1.1 0.7 1.6 23.5 1 585
19 0.75 7/0.37 1.1 0.7 1.7 26.4 1.1 755
24 0.75 7/0.37 1.1 0.7 1.9 31.9 1.3 1030
30 0.75 7/0.37 1.1 0.7 2 34 1.4 1220
37 0.75 7/0.37 1.1 0.7 2.1 36.9 1.5 1450
48 0.75 7/0.37 1.1 0.7 2.3 42.8 1.7 1910

(FA-) TTYC,TTPYC

No. of pair, Triad or Quad Conductor Thick. of insulation Thick. of bedding Dia. of steel wire (FA-) TTYC,TTPYC
Size Construction O.D Nom.overall dia Tolerance Cable Weight
mm² No./mm mm mm mm mm mm mm kg/km
1 0.75 7/0.37 1.1 0.7 1 0.3 9.2 0.4 130
1T 0.75 7/0.37 1.1 0.7 1.1 0.3 9.9 0.4 155
1Q 0.75 7/0.37 1.1 0.7 1.1 0.3 10.6 0.4 180
2 0.75 7/0.37 1.1 0.7 1.2 0.3 13.6 0.6 180
4 0.75 7/0.37 1.1 0.7 1.3 0.3 15.5 0.6 320
7 0.75 7/0.37 1.1 0.7 1.4 0.3 18.2 0.7 440
10 0.75 7/0.37 1.1 0.7 1.5 0.3 23 0.9 640
14 0.75 7/0.37 1.1 0.7 1.6 0.3 24.8 1 770
19 0.75 7/0.37 1.1 0.7 1.7 0.3 27.7 1.1 965
24 0.75 7/0.37 1.1 0.7 1.9 0.4 33.7 1.3 1380
30 0.75 7/0.37 1.1 0.7 2 0.4 35.8 1.4 1590
37 0.75 7/0.37 1.1 0.7 2.1 0.4 38.7 1.5 1860
48 0.75 7/0.37 1.1 0.7 2.3 0.4 44.6 1.7 2380

(FA-) TTYCY,TTPYCY

No. of
pair, Triad or
Quad
Conductor Thick. of
insulation
Thick. of
bedding
Dia. of
steel wire
Thick. of
covering
(FA-) TTYCY,TTPYCY
Size Construction O.D Nom.
overall dia
Tolerance Cable
Weight
mm² No./mm mm mm mm mm mm mm mm kg/km
1 0.75 7/0.37 1.1 0.7 1 0.3 0.8 11 0.4 170
1T 0.75 7/0.37 1.1 0.7 1.1 0.3 0.9 11.7 0.5 205
1Q 0.75 7/0.37 1.1 0.7 1.1 0.3 0.9 12.6 0.5 230
2 0.75 7/0.37 1.1 0.7 1.2 0.3 0.9 15.5 0.7 230
4 0.75 7/0.37 1.1 0.7 1.3 0.3 1 17.7 0.7 400
7 0.75 7/0.37 1.1 0.7 1.4 0.3 1.1 20.6 0.8 545
10 0.75 7/0.37 1.1 0.7 1.5 0.3 1.2 25.6 1 775
14 0.75 7/0.37 1.1 0.7 1.6 0.3 1.2 27.4 1.1 920
19 0.75 7/0.37 1.1 0.7 1.7 0.3 1.3 30.5 1.2 1140
24 0.75 7/0.37 1.1 0.7 1.9 0.4 1.4 36.7 1.5 1610
30 0.75 7/0.37 1.1 0.7 2 0.4 1.5 39.2 1.6 1860
37 0.75 7/0.37 1.1 0.7 2.1 0.4 1.6 42.3 1.6 2170
48 0.75 7/0.37 1.1 0.7 2.3 0.4 1.7 48.4 1.8 2760
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!
There was an error trying to send your message. Please try again later.