Loading...

[FA-] TTY, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCY

Home/JIS C 3410 Shipboard cables/[FA-] TTY, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCY

[FA-] TTY, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCY

Standards

  • JISC 3410-1999
  • IEC 60332-1
  • IEC 60332-3 Cat.A(for FA-type)

Cable Construction

[FA-] TTY,TTYC,TTYCY

ConductorTT
TTP
Tinned annealed stranded copper (TTY-type) Tinned annealed stranded
copper (TTPY-type), class 2 according to IEC 60228
Insulation60°C PVC(TTY-type)/ 85°C EPR(TTPY-type) as per JIS C 3410
TwistingTwo Insulated cores shall be twisted together to form a pair
CablingTwisted pairs shall be cabled.
Flame retardant & non-hygroscopic fillers may be used
BeddingYPVC as per JIS C 3410
ArmorCGalvanized steel wire braid
SheathYPVC as per JIS C 3410
Core identificationPrinted pair number and Alphabet letter on the white insulation.
ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
– 1T, 1Q cable shall be identified by the black number on the white
insulation
Outer sheath colorBlack

Cable Parameter

(FA-) TTY,TTPY

No. of pair, Triad or QuadConductorThick. of insulationThick. of bedding(FA-) TTY,TTPY
SizeConstructionO.DNom.overall diaToleranceCable Weight
mm²No./mmmmmmmmmmmmkg/km
10.757/0.371.10.717.90.470
1T0.757/0.371.10.71.18.60.485
1Q0.757/0.371.10.71.19.30.4105
20.757/0.371.10.71.2120.6105
40.757/0.371.10.71.314.20.6205
70.757/0.371.10.71.416.90.7310
100.757/0.371.10.71.521.70.9465
140.757/0.371.10.71.623.51585
190.757/0.371.10.71.726.41.1755
240.757/0.371.10.71.931.91.31030
300.757/0.371.10.72341.41220
370.757/0.371.10.72.136.91.51450
480.757/0.371.10.72.342.81.71910

(FA-) TTYC,TTPYC

No. of pair, Triad or QuadConductorThick. of insulationThick. of beddingDia. of steel wire(FA-) TTYC,TTPYC
SizeConstructionO.DNom.overall diaToleranceCable Weight
mm²No./mmmmmmmmmmmmmmkg/km
10.757/0.371.10.710.39.20.4130
1T0.757/0.371.10.71.10.39.90.4155
1Q0.757/0.371.10.71.10.310.60.4180
20.757/0.371.10.71.20.313.60.6180
40.757/0.371.10.71.30.315.50.6320
70.757/0.371.10.71.40.318.20.7440
100.757/0.371.10.71.50.3230.9640
140.757/0.371.10.71.60.324.81770
190.757/0.371.10.71.70.327.71.1965
240.757/0.371.10.71.90.433.71.31380
300.757/0.371.10.720.435.81.41590
370.757/0.371.10.72.10.438.71.51860
480.757/0.371.10.72.30.444.61.72380

(FA-) TTYCY,TTPYCY

No. of
pair, Triad or
Quad
ConductorThick. of
insulation
Thick. of
bedding
Dia. of
steel wire
Thick. of
covering
(FA-) TTYCY,TTPYCY
SizeConstructionO.DNom.
overall dia
ToleranceCable
Weight
mm²No./mmmmmmmmmmmmmmmmkg/km
10.757/0.371.10.710.30.8110.4170
1T0.757/0.371.10.71.10.30.911.70.5205
1Q0.757/0.371.10.71.10.30.912.60.5230
20.757/0.371.10.71.20.30.915.50.7230
40.757/0.371.10.71.30.3117.70.7400
70.757/0.371.10.71.40.31.120.60.8545
100.757/0.371.10.71.50.31.225.61775
140.757/0.371.10.71.60.31.227.41.1920
190.757/0.371.10.71.70.31.330.51.21140
240.757/0.371.10.71.90.41.436.71.51610
300.757/0.371.10.720.41.539.21.61860
370.757/0.371.10.72.10.41.642.31.62170
480.757/0.371.10.72.30.41.748.41.82760
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.