Loading...

[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS

Home/JIS C 3410 Shipboard cables/[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS

[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS

Standards

  • JISC 3410-1999
  • IEC 60332-1
  • IEC 60332-3 Cat.A(for FA-type)

Cable Construction

[FA-] TTYS,TTYCS,TTYCYS

ConductorTT
TTP
Tinned annealed stranded copper (TTY-type) Tinned annealed stranded copper (TTPY-type), class 2 according to IEC 60228
Insulation60°C PVC(TTY-type)/ 85°C EPR(TTPY-type) as per JIS C 3410
TwistingTwo Insulated cores shall be twisted together to form a pair
CablingTwisted pairs shall be cabled.
Flame retardant & non-hygroscopic fillers may be used
Overall shieldSTinned copper wire braid
BeddingYPVC as per JIS C 3410
ArmorCGalvanized steel wire braid
SheathYPVC as per JIS C 3410
Core identificationPrinted pair number and Alphabet letter on the white insulation.
ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
– 1T, 1Q cable shall be identified by the black number on the white
insulation
Outer sheath colorBlack

Cable Parameter

(FA-) TTYS,TTPYS

No. of pair, Triad or QuadConductorThick. of insulationDia. of shield wireThick. of bedding(FA-) TTYS,TTPYS
SizeConstructionO.DNom.overall diaToleranceCable Weight
mm²No./mmmmmmmmmmmmmmkg/km
10.757/0.371.10.70.141.18.80.4120
1T0.757/0.371.10.70.141.19.30.4140
1Q0.757/0.371.10.70.141.1100.5160
20.757/0.371.10.70.161.2130.6200
40.757/0.371.10.70.161.3150.7300
70.757/0.371.10.70.161.417.70.8420
100.757/0.371.10.70.181.622.81640
140.757/0.371.10.70.181.624.41770
190.757/0.371.10.70.181.827.51.2970
240.757/0.371.10.70.2233.11.41290
300.757/0.371.10.70.262.135.51.51620
370.757/0.371.10.70.262.238.41.61890
480.757/0.371.10.70.262.444.31.72420

(FA-) TTYCS,TTPYCS

No. of pair, Triad or QuadConductorThick. of insulationDia. of shield wireThick. of beddingDia. of steel wire(FA-) TTYCS,TTPYCS
SizeConstructionO.DNom. overall diaToleranceCable Weight
mm²No./mmmmmmmmmmmmmmmmkg/km
10.757/0.371.10.70.141.10.310.10.4180
1T0.757/0.371.10.70.141.10.310.60.4205
1Q0.757/0.371.10.70.141.10.311.30.5230
20.757/0.371.10.70.161.20.314.60.7230
40.757/0.371.10.70.161.30.316.30.7405
70.757/0.371.10.70.161.40.3190.7545
100.757/0.371.10.70.181.60.324.11800
140.757/0.371.10.70.181.60.325.71935
190.757/0.371.10.70.181.80.328.81.21160
240.757/0.371.10.70.220.434.91.41600
300.757/0.371.10.70.262.10.437.31.51950
370.757/0.371.10.70.262.20.440.21.62250
480.757/0.371.10.70.262.40.446.11.72830

(FA-) TTYCYS,TTPYCYS

No. of pair, Triad or QuadConductorThick.of insulationDia. of shield
wire
Thick. of beddingDia.of steel wireThick. of covering(FA-) TTYCYS,TTPYCYS
SizeConstructionO.DNom.
overall dia
ToleranceCable
Weight
mm²No./mmmmmmmmmmmmmmmmmmkg/km
10.757/0.371.10.70.141.10.30.912.10.5230
1T0.757/0.371.10.70.141.10.30.912.60.5255
1Q0.757/0.371.10.70.141.10.30.913.30.5285
20.757/0.371.10.70.161.20.3116.70.7285
40.757/0.371.10.70.161.30.3118.50.7490
70.757/0.371.10.70.161.40.31.121.40.9650
100.757/0.371.10.70.181.60.31.226.71.1945
140.757/0.371.10.70.181.60.31.228.31.11090
190.757/0.371.10.70.181.80.31.331.61.31340
240.757/0.371.10.70.220.41.538.31.51860
300.757/0.371.10.70.262.10.41.540.71.62230
370.757/0.371.10.70.262.20.41.643.81.72570
480.757/0.371.10.70.262.40.41.850.11.83240
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!
There was an error trying to send your message. Please try again later.

MRE-2X(St)HCH 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened & Armoured Flame RetardantInstrumentation & Control Cables (Multipair/Multitriple)

Go to Top