[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS

Home/JIS C 3410 Shipboard cables/[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS

[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS

Standards

  • JISC 3410-1999
  • IEC 60332-1
  • IEC 60332-3 Cat.A(for FA-type)

Cable Construction

[FA-] TTYS,TTYCS,TTYCYS

Conductor TT
TTP
Tinned annealed stranded copper (TTY-type) Tinned annealed stranded copper (TTPY-type), class 2 according to IEC 60228
Insulation 60°C PVC(TTY-type)/ 85°C EPR(TTPY-type) as per JIS C 3410
Twisting Two Insulated cores shall be twisted together to form a pair
Cabling Twisted pairs shall be cabled.
Flame retardant & non-hygroscopic fillers may be used
Overall shield S Tinned copper wire braid
Bedding Y PVC as per JIS C 3410
Armor C Galvanized steel wire braid
Sheath Y PVC as per JIS C 3410
Core identification Printed pair number and Alphabet letter on the white insulation.
ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
– 1T, 1Q cable shall be identified by the black number on the white
insulation
Outer sheath color Black

Cable Parameter

(FA-) TTYS,TTPYS

No. of pair, Triad or Quad Conductor Thick. of insulation Dia. of shield wire Thick. of bedding (FA-) TTYS,TTPYS
Size Construction O.D Nom.overall dia Tolerance Cable Weight
mm² No./mm mm mm mm mm mm mm kg/km
1 0.75 7/0.37 1.1 0.7 0.14 1.1 8.8 0.4 120
1T 0.75 7/0.37 1.1 0.7 0.14 1.1 9.3 0.4 140
1Q 0.75 7/0.37 1.1 0.7 0.14 1.1 10 0.5 160
2 0.75 7/0.37 1.1 0.7 0.16 1.2 13 0.6 200
4 0.75 7/0.37 1.1 0.7 0.16 1.3 15 0.7 300
7 0.75 7/0.37 1.1 0.7 0.16 1.4 17.7 0.8 420
10 0.75 7/0.37 1.1 0.7 0.18 1.6 22.8 1 640
14 0.75 7/0.37 1.1 0.7 0.18 1.6 24.4 1 770
19 0.75 7/0.37 1.1 0.7 0.18 1.8 27.5 1.2 970
24 0.75 7/0.37 1.1 0.7 0.2 2 33.1 1.4 1290
30 0.75 7/0.37 1.1 0.7 0.26 2.1 35.5 1.5 1620
37 0.75 7/0.37 1.1 0.7 0.26 2.2 38.4 1.6 1890
48 0.75 7/0.37 1.1 0.7 0.26 2.4 44.3 1.7 2420

(FA-) TTYCS,TTPYCS

No. of pair, Triad or Quad Conductor Thick. of insulation Dia. of shield wire Thick. of bedding Dia. of steel wire (FA-) TTYCS,TTPYCS
Size Construction O.D Nom. overall dia Tolerance Cable Weight
mm² No./mm mm mm mm mm mm mm mm kg/km
1 0.75 7/0.37 1.1 0.7 0.14 1.1 0.3 10.1 0.4 180
1T 0.75 7/0.37 1.1 0.7 0.14 1.1 0.3 10.6 0.4 205
1Q 0.75 7/0.37 1.1 0.7 0.14 1.1 0.3 11.3 0.5 230
2 0.75 7/0.37 1.1 0.7 0.16 1.2 0.3 14.6 0.7 230
4 0.75 7/0.37 1.1 0.7 0.16 1.3 0.3 16.3 0.7 405
7 0.75 7/0.37 1.1 0.7 0.16 1.4 0.3 19 0.7 545
10 0.75 7/0.37 1.1 0.7 0.18 1.6 0.3 24.1 1 800
14 0.75 7/0.37 1.1 0.7 0.18 1.6 0.3 25.7 1 935
19 0.75 7/0.37 1.1 0.7 0.18 1.8 0.3 28.8 1.2 1160
24 0.75 7/0.37 1.1 0.7 0.2 2 0.4 34.9 1.4 1600
30 0.75 7/0.37 1.1 0.7 0.26 2.1 0.4 37.3 1.5 1950
37 0.75 7/0.37 1.1 0.7 0.26 2.2 0.4 40.2 1.6 2250
48 0.75 7/0.37 1.1 0.7 0.26 2.4 0.4 46.1 1.7 2830

(FA-) TTYCYS,TTPYCYS

No. of pair, Triad or Quad Conductor Thick.of insulation Dia. of shield
wire
Thick. of bedding Dia.of steel wire Thick. of covering (FA-) TTYCYS,TTPYCYS
Size Construction O.D Nom.
overall dia
Tolerance Cable
Weight
mm² No./mm mm mm mm mm mm mm mm mm kg/km
1 0.75 7/0.37 1.1 0.7 0.14 1.1 0.3 0.9 12.1 0.5 230
1T 0.75 7/0.37 1.1 0.7 0.14 1.1 0.3 0.9 12.6 0.5 255
1Q 0.75 7/0.37 1.1 0.7 0.14 1.1 0.3 0.9 13.3 0.5 285
2 0.75 7/0.37 1.1 0.7 0.16 1.2 0.3 1 16.7 0.7 285
4 0.75 7/0.37 1.1 0.7 0.16 1.3 0.3 1 18.5 0.7 490
7 0.75 7/0.37 1.1 0.7 0.16 1.4 0.3 1.1 21.4 0.9 650
10 0.75 7/0.37 1.1 0.7 0.18 1.6 0.3 1.2 26.7 1.1 945
14 0.75 7/0.37 1.1 0.7 0.18 1.6 0.3 1.2 28.3 1.1 1090
19 0.75 7/0.37 1.1 0.7 0.18 1.8 0.3 1.3 31.6 1.3 1340
24 0.75 7/0.37 1.1 0.7 0.2 2 0.4 1.5 38.3 1.5 1860
30 0.75 7/0.37 1.1 0.7 0.26 2.1 0.4 1.5 40.7 1.6 2230
37 0.75 7/0.37 1.1 0.7 0.26 2.2 0.4 1.6 43.8 1.7 2570
48 0.75 7/0.37 1.1 0.7 0.26 2.4 0.4 1.8 50.1 1.8 3240