Loading...

[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS

Home/JIS C 3410 Shipboard cables/[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS

[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS

Standards

  • JISC 3410-1999
  • IEC 60332-1
  • IEC 60332-3 Cat.A(for FA-type)

Cable Construction

[FA-] TTYS,TTYCS,TTYCYS

ConductorTT
TTP
Tinned annealed stranded copper (TTY-type) Tinned annealed stranded copper (TTPY-type), class 2 according to IEC 60228
Insulation60°C PVC(TTY-type)/ 85°C EPR(TTPY-type) as per JIS C 3410
TwistingTwo Insulated cores shall be twisted together to form a pair
CablingTwisted pairs shall be cabled.
Flame retardant & non-hygroscopic fillers may be used
Overall shieldSTinned copper wire braid
BeddingYPVC as per JIS C 3410
ArmorCGalvanized steel wire braid
SheathYPVC as per JIS C 3410
Core identificationPrinted pair number and Alphabet letter on the white insulation.
ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
– 1T, 1Q cable shall be identified by the black number on the white
insulation
Outer sheath colorBlack

Cable Parameter

(FA-) TTYS,TTPYS

No. of pair, Triad or QuadConductorThick. of insulationDia. of shield wireThick. of bedding(FA-) TTYS,TTPYS
SizeConstructionO.DNom.overall diaToleranceCable Weight
mm²No./mmmmmmmmmmmmmmkg/km
10.757/0.371.10.70.141.18.80.4120
1T0.757/0.371.10.70.141.19.30.4140
1Q0.757/0.371.10.70.141.1100.5160
20.757/0.371.10.70.161.2130.6200
40.757/0.371.10.70.161.3150.7300
70.757/0.371.10.70.161.417.70.8420
100.757/0.371.10.70.181.622.81640
140.757/0.371.10.70.181.624.41770
190.757/0.371.10.70.181.827.51.2970
240.757/0.371.10.70.2233.11.41290
300.757/0.371.10.70.262.135.51.51620
370.757/0.371.10.70.262.238.41.61890
480.757/0.371.10.70.262.444.31.72420

(FA-) TTYCS,TTPYCS

No. of pair, Triad or QuadConductorThick. of insulationDia. of shield wireThick. of beddingDia. of steel wire(FA-) TTYCS,TTPYCS
SizeConstructionO.DNom. overall diaToleranceCable Weight
mm²No./mmmmmmmmmmmmmmmmkg/km
10.757/0.371.10.70.141.10.310.10.4180
1T0.757/0.371.10.70.141.10.310.60.4205
1Q0.757/0.371.10.70.141.10.311.30.5230
20.757/0.371.10.70.161.20.314.60.7230
40.757/0.371.10.70.161.30.316.30.7405
70.757/0.371.10.70.161.40.3190.7545
100.757/0.371.10.70.181.60.324.11800
140.757/0.371.10.70.181.60.325.71935
190.757/0.371.10.70.181.80.328.81.21160
240.757/0.371.10.70.220.434.91.41600
300.757/0.371.10.70.262.10.437.31.51950
370.757/0.371.10.70.262.20.440.21.62250
480.757/0.371.10.70.262.40.446.11.72830

(FA-) TTYCYS,TTPYCYS

No. of pair, Triad or QuadConductorThick.of insulationDia. of shield
wire
Thick. of beddingDia.of steel wireThick. of covering(FA-) TTYCYS,TTPYCYS
SizeConstructionO.DNom.
overall dia
ToleranceCable
Weight
mm²No./mmmmmmmmmmmmmmmmmmkg/km
10.757/0.371.10.70.141.10.30.912.10.5230
1T0.757/0.371.10.70.141.10.30.912.60.5255
1Q0.757/0.371.10.70.141.10.30.913.30.5285
20.757/0.371.10.70.161.20.3116.70.7285
40.757/0.371.10.70.161.30.3118.50.7490
70.757/0.371.10.70.161.40.31.121.40.9650
100.757/0.371.10.70.181.60.31.226.71.1945
140.757/0.371.10.70.181.60.31.228.31.11090
190.757/0.371.10.70.181.80.31.331.61.31340
240.757/0.371.10.70.220.41.538.31.51860
300.757/0.371.10.70.262.10.41.540.71.62230
370.757/0.371.10.70.262.20.41.643.81.72570
480.757/0.371.10.70.262.40.41.850.11.83240