MFX300 0.6/1 kV Fire Barriers + HEPR Insulated, LSOH (SHF1)Sheathed, Screened Fire Resistant Power & Control Cables(Single Core)
Application
These cables are used for fixed installations on ships and offshore units in all locations and on open deck in safety circuits, where fire resistance is required. The good screening qualities of the copper braid also reduce radio interference and electrical influences to electronics installations. These cables are fire resistant, flame retardant, low smoke & halogen free.
Standards
- DIN 89160/98
- IEC 60092-353
- IEC 60331-21
- IEC 60332-1
- IEC 60332-3-22
- IEC 60754-1/2
- IEC 61034
Construction
- Conductors: Class 2 stranded copper conductor.
- Insulation: Fire barriers + HEPR.
- Overall Screen: Copper wire braid.
- Outer Sheath: LSOH (SHF1).
Core Identification
Single core: Natural colour (beige).
Mechanical and Thermal Properties
- Bending Radius for Fixed Installations: 6×OD
- Temperature Range: -20℃ ~ +75℃
Dimensions and Weight
Part No. | Construction No. of cores×Cross section(mm²) | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
MFX300-1mG7MZ1-R-1C25 | 1×25 | 0.9 | 1.2 | 12.5 | 380 |
MFX300-1mG7MZ1-R-1C35 | 1×35 | 0.9 | 1.2 | 13.5 | 480 |
MFX300-1mG7MZ1-R-1C50 | 1×50 | 1.0 | 1.3 | 15.5 | 670 |
MFX300-1mG7MZ1-R-1C70 | 1×70 | 1.1 | 1.4 | 17.5 | 900 |
MFX300-1mG7MZ1-R-1C95 | 1×95 | 1.1 | 1.4 | 19.5 | 1170 |
MFX300-1mG7MZ1-R-1C120 | 1×120 | 1.6 | 1.5 | 21.0 | 1430 |