Loading...

Mud Resistant Cat 7 S/FTP 0.27 mm²

Home/IEC60092 Offshore & Marine Cables/Mud Resistant Cat 7 S/FTP 0.27 mm²

Mud Resistant Cat 7 S/FTP 0.27 mm²

Application

These Cat7 S/FTP cables are manufactured in accordance with IEC 61156-5 requirements,can support all Class F applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for voice, data, CATV and sharing application installations up to 600MHz. These cables have additional flame retardant, halogen-free, low smoke MUD protecting outer sheaths.

Standards

  • EN 50173-1
  • EN 50288-4-1
  • ISO/IEC 11801
  • IEC 61156-5
  • IEC 60332-3-24
  • IEC 60754-2
  • IEC 61034

Construction

Mud Resistant Cat 7 S/FTP 0.27 mm²

  • Conductors: Stranded copper conductor.
  • Insulation: PE.
  • Twinning: Two coloured insulated conductors twisted together to form a pair.
  • Individual Screen: Al/polyester tape.
  • Overall Screen: Tinned copper wire braid.
  • Inner Sheath: Oil resistant, flame retardant and halogen free LSOH (SHF1).
  • Outer Sheath: MUD protecting.

Core Identification

  • Pair 1: White, Blue
  • Pair 2: White, Orange
  • Pair 3: White, Green
  • Pair 4: White, Brown

Electrical Properties

Characteristic Impedance(1-250MHz)Ω100±15
Characteristic Impedance(100-500MHz)Ω100±22
Nominal Velocity of Propagation(NVP)79%
Maximum Mutual CapacitancenF/100m5.6
Maximum Resistance Unbalance5%
Maximum Propagation Delay Skew(1-125MHz)ns/100m30
Maximum Propagation Delay@100MHzns/100m536
Voltage RatingV rms60

Nominal Transmission Characteristics @20℃

FREQNEXTAttenuationRLACRELFEXTPSNEXTPSACRPSELFEXT
MHzdB/100mdB/100mdB/100mdB/100mdB/100mdB/100mdB/100mdB/100m
1802207880777577
4803.62376.4807773.477
10805.72574.3747771.371
16807.22572.869.97769.866.9
20808.12571.9687768.965
31.38010.123.669.964.17766.961.1
62.575.514.521.56158.172.55855.1
10072.418.520.153.95469.450.951
20067.926.81841.17864.938.145
25066.530.217.336.34663.533.343
30065.333.317.33244.563.32941.5
60060.848.917.311.938.457.88.935.4

Mechanical and Thermal Properties

  • Bending Radius: 8×OD (during installation); 4×OD (fixed installed)
  • Temperature Range: -20℃ ~ +60℃

Dimensions and Weight

Part No.Construction No. of elements×No. of cores in element×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmNominal Overall Diameter mmNominal Weight kg/km
InnerOuter
MLN-S/FTPCAT7M4P27S4×2×0.270.470.751.010.1112

 