Loading...

P34 BFOU-HCF 0.6/1 kV Cables

Home/NEK 606 Offshore & Marine Cables/P34 BFOU-HCF 0.6/1 kV Cables

P34 BFOU-HCF 0.6/1 kV Cables Applications

P34 BFOU-HCF 0.6/1 kV Cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency control, power and lighting systems that need to be operational during a 1100℃ hydrocarbon fire.

P34 BFOU-HCF 0.6/1 kV Cables Standards

IEC 60092-353IEC 60092-351
IEC 60092-359IEC 60332-1
IEC 60332-3-22IEC 60754-1,2
IEC 61034-1,2NEK 606:2004
P34 BFOU-HCF 0.6/1 kVP34 BFOU-HCF 0.6/1 kV

P34 BFOU-HCF 0.6/1 kV Cables Construction

  • Conductors : Tinned annealed stranded compacted copper to IEC 60228 class 2.
  • Insulation : Mica tape + Halogen free EPR/XLPE.
  • Bedding : Halogen free compound.
  • Armour : Tinned copper wire braid.
  • Outer Sheath1 : Halogen free thermosetting compound, SHF2.
  • HC-fire protection : Extruded thermoplastic fire protection compound.
  • Taping : Lapped glass fibre tape.
  • Outer Sheath2 : Flame retardant halogen-free thermoplastic compound, SHF1, coloured black.

P34 BFOU-HCF 0.6/1 kV Cables Electrical Characteristics

Nominal Cross Section Areamm²1.52.5461635
Nominal Conductor Diametermm1.62.12.63.25.17.4
Maximum DC Resistant@20℃Ω/km12.27.564.73.111.160.529
Continuous Current Rating@45℃1 CoreA2330405296157
Continuous Current Rating@45℃2 CoreA2026344482133
Continuous Current Rating@45℃3&4 CoreA1621283667110
Short Circuit Current 1sA21036057086022905010
Operating VoltageKV0.6/10.6/10.6/10.6/10.6/10.6/1

 

Nominal Cross Section Areamm²507095120150185240300
Nominal Conductor Diametermm8.710.312.213.815.117.019.621.9
Maximum DC Resistant@20℃Ω/km0.3910.270.1950.1540.1260.10.07620.0607
Continuous Current Rating@45℃1 CoreA196242293339389444522601
Continuous Current Rating@45℃2 CoreA167206249288331444444511
Continuous Current Rating@45℃3&4 CoreA137169205237272311365421
Short Circuit Current 1sA715010020135901717021460264703434042930
Operating VoltageKV0.6/10.6/10.6/10.6/10.6/10.6/10.6/10.6/1

Note: For more than 4-cores, the current ratings may be calculated from the following formula (IN=I1/ ³√ N ), I1= Current rating for 1-core, N = Number of cores.

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors35404550556065707580
Rating Factor1.11.051.00.940.880.820.740.670.580.47

Mechanical and Thermal Properties

  • Bending Radius :20×OD (during installation); 12×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

P34 BFOU-HCF 0.6/1 kV Cables Dimensions and Weight

Construction No. of cores×Cross section
(mm²)
Nominal Insulation Thickness
mm
Nominal Diameter Over Bedding
mm
Nominal Diameter Over Sheath1
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
1×501.415.018.545.52900
1×701.416.520.547.53300
1×951.618.523.050.53800
1×1201.620.525.052.54260
1×1501.823.027.054.54750
1×1852.025.029.557.55380
1×2402.228.032.566.07050
1×3002.430.535.568.08000
2×1.51.010.013.040.51890
2×2.51.011.014.542.02080
3×1.51.010.514.042.02140
3×2.51.011.515.042.52200
3×41.013.016.543.02400
3×61.014.018.045.02600
3×161.018.523.050.03500
3×351.225.029.557.54840
3×701.433.039.072.08150
3×1201.641.048.081.511300
3×1501.846.054.588.513300
4×2.51.012.516.544.02300
4×61.015.519.547.52870
4×161.020.525.053.53830
7×1.51.014.017.544.52550
12×1.51.018.522.550.03140
27×1.51.026.531.064.55070
7×2.51.015.019.046.02760
12×2.51.020.524.552.03500
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!