Loading...

P4 or P4/P11 RFOU/TFOU 8.7/15KV

Home/NEK 606 Offshore & Marine Cables/P4 or P4/P11 RFOU/TFOU 8.7/15KV

P4 or P4/P11 RFOU/TFOU 8.7/15KV Applications

These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.

P4 or P4/P11 RFOU/TFOU 8.7/15KV Standards

IEC 60092-353IEC 60092-351
IEC 60092-359IEC 60332-1
IEC 60332-3-22IEC 60754-1,2
IEC 61034-1,2NEK 606:2004
P4 or P4/P11 RFOU/TFOU 8.7/15KVP4 or P4/P11 RFOU/TFOU 8.7/15KV

P4 or P4/P11 RFOU/TFOU 8.7/15KV Construction

  • Conductors : Circular tinned annealed stranded copper to IEC 60228 class 2.
  • Conductor Screen : Semi conducting material.
  • Insulation : Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).
  • Insulation Screen : Semi conducting material and tinned copper wire braid.
  • Bedding : Halogen free compound.
  • Armour : Tinned copper wire braid.
  • Outer Sheath :Halogen free thermosetting compound, SHF2 (for TYPE P4), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P4/P11), coloured red.

Electrical Characteristics

Nominal Cross Section Areamm²2535507095120
Nominal Conductor Diametermm6.57.48.710.312.213.8
Maximum DC Resistant@20℃Ω/km0.7340.5290.3910.270.1950.154
Continuous Current Rating@45℃1 CoreA127157196242293339
Continuous Current Rating@45℃3 CoreA89110137169205237
Short Circuit Current 1sA358050107150100201359017170
Operating VoltageKV8.7/158.7/158.7/158.7/158.7/158.7/15

 

Nominal Cross Section Areamm²150185240300400500630
Nominal Conductor Diametermm15.117.019.621.924.527.532.3
Maximum DC Resistant@20℃Ω/km0.1260.10.07620.06070.04750.03690.0286
Continuous Current Rating@45℃1 CoreA389444522601690780890
Continuous Current Rating@45℃3 CoreA272311365421483546623
Short Circuit Current 1sA21460264703434042930572307154090140
Operating VoltageKV8.7/158.7/158.7/158.7/158.7/158.7/158.7/15

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors35404550556065707580
Rating Factor1.11.051.00.940.880.820.740.670.580.47

Mechanical and Thermal Properties

  • Bending Radius :15×OD (during installation); 9×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

P4 or P4/P11 RFOU/TFOU 8.7/15KV Dimensions and Weight

Construction No. of cores×Cross section
(mm²)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
InnerOuter
1×254.51.61.228.41305
1×354.51.61.329.31430
1×504.51.71.330.71620
1×704.51.81.332.41900
1×954.51.81.434.42250
1×1204.51.91.536.62625
1×1504.52.01.538.12940
1×1854.52.01.540.63545
1×2404.52.11.643.44220
1×3004.52.21.746.35070
1×4004.52.41.850.25760
1×5004.52.51.853.66880
1×6304.52.61.957.98460
3×254.52.61.955.34725
3×354.52.72.057.55215
3×504.52.82.060.65960
3×704.52.92.164.47035
3×954.53.12.268.78370
3×1204.53.22.372.79745
3×1504.53.42.476.811140
3×1854.53.62.684.213490
3×2404.53.82.790.615860
3×3004.54.02.996.618320
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!
There was an error trying to send your message. Please try again later.

MRE-M2XCH PiMF/TiMF 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Individual Screened & Armoured Fire Resistant Instrumentation & Control Cables (Multipair/Multitriple)