PROFIBUS 1 Pair 0.35mm²
Application
These profibus cables are dedicated for fixed installation on board of ship, used as connection cables for digital signals up to 12MBd.
Standards
- DIN VDE 0472 part 805
- IEC 60332-1&2
- IEC 60754-1/2
- IEC 61034
Construction
- Conductors: Stranded bare copper.
- Insulation: Foam polyethylene (cellular HDPE).
- Overall Screen1: Aluminium/polyester tape.
- Overall Screen2: Tinned copper braid.
- Inner Sheath: Halogen-free polymer HM4.
- Outer Sheath: LSOH (SHF1).
Core Identification
- Core 1: Red
- Core 2: Green
Electrical Properties
Characteristic Impedance | Ω | 150 ± 15 |
Mutual Capacitance @1KHz | nF/km | 30 |
Insulation Resistance | MΩ.km | 16000 |
Attenuation @9.6kHz | dB/km | 3 |
Attenuation @38.4kHz | dB/km | 5 |
Attenuation @4kHz | dB/km | 22 |
Attenuation @16kHz | dB/km | 45 |
Mechanical and Thermal Properties
- Bending Radius for Fixed Installations: 10×OD
- Temperature Range: -35℃ ~ +80℃
Dimensions and Weight
Part No. | Construction No. of elements×No. of cores in element×Cross section(mm²) | Core Diameter mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
MLN-02Y(ST)CH-1×2×0.35 | 1×2×0.35 | 2.75 | 10.3 | 110 |
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.