Loading...

Water Blocked P19 or P19/P21 RFOU 12/20KV

Home/Water Blocked NEK 606 Offshore & Marine Cables/Water Blocked P19 or P19/P21 RFOU 12/20KV

Water Blocked P19 or P19/P21 RFOU 12/20KV

Applications

These cables are partially water blocked, flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.

Standards

IEC 60092-353IEC 60092-351
IEC 60092-359IEC 60332-1
IEC 60332-3-22IEC 60754-1,2
IEC 61034-1,2NEK 606:2004
VG 95218 part 29
Water Blocked P19 or P19/P21 RFOU 12/20KV

Construction

Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2.
Conductor Screen: Semi conducting material.
Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).
Insulation Screen: Semi conducting material and tinned copper wire braid.
Filler: Water blocking fillers, if required.
Bedding: Halogen free compound, PETP wrapping tape will be applied over the bedding, if required.
Armour: Tinned copper wire braid, PETP wrapping tape will be applied over the braiding, if required.
Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.
Inner Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P19), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P19/P21), coloured red.
Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.

Optional

P20 or P20/P22 RFOU/TFOU 18/30(36) kV.

Electrical Characteristics

Nominal Cross Section Areamm²162535507095
Nominal Conductor Diametermm5.26.57.48.710.312.2
Maximum DC Resistant@20℃Ω/km1.160.7340.5290.3910.270.195
Continuous Current Rating@45℃1 CoreA96127157196242293
Continuous Current Rating@45℃3 CoreA6789110137169205
Short Circuit Current 1sA22903580501071501002013590
Operating VoltageKV12/2012/2012/2012/2012/2012/20

 

Nominal Cross Section Areamm²120150185240300
Nominal Conductor Diametermm13.815.117.019.621.9
Maximum DC Resistant@20℃Ω/km0.1540.1260.10.07620.0607
Continuous Current Rating@45℃1 CoreA339389444522601
Continuous Current Rating@45℃3 CoreA237272311365421
Short Circuit Current 1sA1717021460264703434042930
Operating VoltageKV12/2012/2012/2012/2012/20

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors35404550556065707580
Rating Factor1.11.051.00.940.880.820.740.670.580.47

Mechanical and Thermal Properties

  • Bending Radius :15×OD (during installation); 9×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight

Construction No. of cores×Cross section

(mm²)

Nominal Insulation Thickness mmNominal Bedding Thickness mmNominal Inner Sheath Thickness mmNominal Outer Sheath Thickness mm
Nominal Overall Diameter

mm

Nominal Weight

kg/km

1×165.51.41.2130.0±21260
1×255.51.51.21.234.0±21607
1×355.51.81.31.234.7±21675
1×505.51.81.41.236.2±21885
1×705.51.91.41.237.0±22174
1×955.521.51.439.8±22594
1×1205.521.51.441.6±22951
1×1505.52.11.61.443.5±23407
1×1855.52.21.61.445.7±23953
1×2405.52.31.71.649.0±24736
1×3005.52.41.81.651.7±25581
3×165.51.82157.1±25198
3×255.51.921.264.6±25990
3×355.52.92.11.265.0±26290
3×505.532.21.267.8±27077
3×705.53.12.31.271.5±28180
3×955.53.32.41.475.8±29608
3×1205.53.42.51.479.8±211109
3×1505.53.62.61.484.7±212752
3×1855.53.82.71.492.3±212878
3×2405.542.91.699.3±215461
3×3005.54.231.6105.1±218050
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!
There was an error trying to send your message. Please try again later.

MRE-M2X(St)CH 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened & Armoured Fire Resistant Instrumentation & Control Cables (Multipair/Multitriple)