Loading...

Water Blocked P2 or P2/P9 RFOU/TFOU 3.6/6KV

Home/Water Blocked NEK 606 Offshore & Marine Cables/Water Blocked P2 or P2/P9 RFOU/TFOU 3.6/6KV

Water Blocked P2 or P2/P9 RFOU/TFOU 3.6/6KV

Applications

These cables are partially water blocked, flame retardant, low smoke, halogen-free and mud resistant, used for fixed installation for medium voltage power.

Standards

IEC 60092-353IEC 60092-351
IEC 60092-359IEC 60332-1
IEC 60332-3-22IEC 60754-1,2
IEC 61034-1,2NEK 606:2004
VG 95218 part 29

 

Water Blocked P2 or P2/P9 RFOU/TFOU 3.6/6KV

 

Construction

Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2.
Conductor Screen: Semi conducting material.
Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).
Insulation Screen: Semi conducting material and tinned copper wire braid.
Filler: Water blocking fillers, if required.
Bedding: Halogen free compound, PETP wrapping tape will be applied over the bedding, if required.
Armour: Tinned copper wire braid, PETP wrapping tape will be applied over the braiding, if required.
Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.
Inner Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P2), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P2/P9), coloured red.
Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.

Electrical Characteristics

Nominal Cross Section Areamm²162535507095120
Nominal Conductor Diametermm5.16.57.48.710.312.213.8
Maximum DC Resistant@20℃Ω/km1.160.7340.5290.3910.270.1950.154
Continuous Current Rating@45℃1 CoreA96127157196242293339
Continuous Current Rating@45℃3 CoreA6789110137169205237
Short Circuit Current 1sA2290358050107150100201359017170
Operating VoltageKV3.6/63.6/63.6/63.6/63.6/63.6/63.6/6

 

Nominal Cross Section Areamm²150185240300400500630
Nominal Conductor Diametermm15.117.019.621.924.627.632.5
Maximum DC Resistant@20℃Ω/km0.1260.10.07620.06070.04750.03690.0286
Continuous Current Rating@45℃1 CoreA389444522601690780890
Continuous Current Rating@45℃3 CoreA272311365421483546623
Short Circuit Current 1sA21460264703434042930572307154090140
Operating VoltageKV3.6/63.6/63.6/63.6/63.6/63.6/63.6/6

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors35404550556065707580
Rating Factor1.11.051.00.940.880.820.740.670.580.47

Mechanical and Thermal Properties

Bending Radius :15×OD (during installation); 9×OD (fixed installed).
Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight

Construction No. of cores×Cross section

(mm²)

Nominal Insulation Thickness

mm

Nominal BeddingThickness

mm

NominalInner Sheath Thickness

mm

NominalOuter Sheath Thickness

mm

Nominal Overall

Diameter

mm

Nominal Weight

kg/km

1×162.51.41.1124.8±2819
1×252.51.51.11.226.4±21071
1×352.51.51.21.227.5±21213
1×502.51.61.21.228.7±21386
1×702.51.61.31.230.6±21675
1×952.51.71.31.432.8±22000
1×1202.51.81.41.434.6±22347
1×1502.51.81.41.436.3±22678
1×1852.51.91.51.438.0±23166
1×2402.621.51.642.0±23911
1×3002.82.11.61.645.5±24856
1×40032.21.71.649.8±25691
1×5003.22.41.81.654.0±26941
1×6303.22.51.91.658.3±28579
3×162.52.21.6146.9±23077
3×252.52.31.71.247.8±23560
3×352.52.41.81.250.0±24011
3×502.52.51.91.253.3±24720
3×702.52.721.257.2±25864
3×952.52.82.11.461.7±27103
3×1202.532.21.466.3±28573
3×1502.53.12.31.470.2±29970
3×1852.53.32.41.478.6±211193
3×2402.63.52.51.685.5±212243
3×3002.83.82.71.692.5±213587
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!
There was an error trying to send your message. Please try again later.