Loading...

Water Blocked P30 RFOU-HCF / TFOU-HCF 6/10(12) kV

Home/Water Blocked NEK 606 Offshore & Marine Cables/Water Blocked P30 RFOU-HCF / TFOU-HCF 6/10(12) kV

Water Blocked P30 RFOU-HCF / TFOU-HCF 6/10(12) kV

Applications

These cables are partially water blocked, fire-resistant, flame retardant, low smoke and halogen-free, used for emergency control, power and lighting systems that need to be operational during a 1100˚C hydrocarbon fire.

Standards

IEC 60092-354IEC 60092-351
IEC 60092-359IEC 60332-1
IEC 60331-21IEC 60332-3-22
IEC 60754-1,2IEC 61034-1,2
NEK 606:2004VG 95218 part 29

 

water blocked P30 RFOU-HCF / TFOU-HCF 6/10(12) kV

Construction

Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2.
Conductor Screen: Semi conducting material.
Insulation: Halogen-free EPR. XLPE can be offered as an option.
Insulation Screen: Semi conducting material and tinned copper wire braid.
Filler: Water blocking fillers, if required.
Bedding: Halogen-free compound, PETP wrapping tape will be applied over the bedding, if required.
Armour: Tinned copper wire braid, PETP wrapping tape will be applied over the braiding, if required.
Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.
Inner Sheath: Halogen-free thermosetting compound, SHF2, colored red.
HC-fire protection: Extruded thermoplastic fire protection compound.
Taping: Lapped glass fiber tape.

Outer Sheath 1: Flame retardant halogen-free thermoplastic compound, SHF1, coloured red.
Outer Sheath 2: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.

Optional

  • P31 RFOU-HCF / TFOU-HCF 8.7/15kV
  • P32 RFOU-HCF / TFOU-HCF 12/20(24) kV
  • P33 RFOU-HCF / TFOU-HCF 18/30(36) kV

Electrical Characteristics

Nominal Cross Section Areamm²7095120150185240300
Nominal Conductor Diametermm10.312.213.815.117.019.621.9
Maximum DC Resistant@20℃Ω/km0.270.1950.1540.1260.10.07620.0607
Continuous Current Rating@45℃1 CoreA242293339389444522601
Continuous Current Rating@45℃3 CoreA169205237272311365421
Short Circuit Current 1sA10020135901717021460264703434042930
Operating VoltageKV6/106/106/106/106/106/106/10

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors35404550556065707580
Rating Factor1.11.051.00.940.880.820.740.670.580.47

Mechanical and Thermal Properties

  • Bending Radius : 25×OD (during installation); 12×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight

Construction No. of cores×Cross section

(mm²)

Nominal Insulation Thickness

mm

Nominal Diameter Over Bedding

mm

Nominal Diameter Over Inner Sheath

mm

Nominal Overall Diameter

mm

Nominal Weight

kg/km

1×703.423.53064.4±25481
1×953.425.53267.3±26195
1×1203.427.53469.3±26657
1×1503.428.53570.3±27004
1×1853.430.536.571.8±27686
1×2403.4333975.2±28663
1×3003.43541.577.7±29744
3×503.4475591.4±211519
3×953.45462.599.8±214942
3×1503.46070.5108.8±218270

 