Loading...

Water Blocked P34 BFOU-HCF 0.6/1 kV

Home/Water Blocked NEK 606 Offshore & Marine Cables/Water Blocked P34 BFOU-HCF 0.6/1 kV

Water Blocked P34 BFOU-HCF 0.6/1 kV

Applications

These cables are partially water blocked, fire-resistant, flame retardant, low smoke and halogen-free, used for emergency control, power, and lighting systems that need to be operational during a 1100˚C hydrocarbon fire.

Standards

IEC 60092-353IEC 60092-351
IEC 60092-359IEC 60332-1
IEC 60332-3-22IEC 60754-1,2
IEC 61034-1,2NEK 606:2004
VG 95218 part 29

 

Water Blocked P34 BFOU-HCF 0.6/1 kV

Construction

Conductors: Tinned annealed stranded compacted copper to IEC 60228 class 2.
Insulation: Mica tape + Halogen free EPR/XLPE.
Filler: Water blocking fillers, if required.
Bedding: Halogen free compound, PETP wrapping tape will be applied over the bedding, if required.
Armour: Tinned copper wire braid, PETP wrapping tape will be applied over the braiding, if required.
Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.
Inner Sheath: Halogen free thermosetting compound, SHF2.
HC-fire protection: Extruded thermoplastic fire protection compound.
Taping: Lapped glass fibre tape.
Outer Sheath 1: Flame retardant halogen-free thermoplastic compound, SHF1, coloured black.

Outer Sheath 2: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.

Electrical Characteristics

Nominal Cross Section Areamm²1.52.5461635
Nominal Conductor Diametermm1.62.12.63.25.17.4
Maximum DC Resistant@20℃Ω/km12.27.564.73.111.160.529
Continuous Current Rating@45℃1 CoreA2330405296157
Continuous Current Rating@45℃2 CoreA2026344482133
Continuous Current Rating@45℃3&4 CoreA1621283667110
Short Circuit Current 1sA21036057086022905010
Operating VoltageKV0.6/10.6/10.6/10.6/10.6/10.6/1

 

Nominal Cross Section Areamm²507095120150185240300
Nominal Conductor Diametermm8.710.312.213.815.117.019.621.9
Maximum DC Resistant@20℃Ω/km0.3910.270.1950.1540.1260.10.07620.0607
Continuous Current Rating@45℃1 CoreA196242293339389444522601
Continuous Current Rating@45℃2 CoreA167206249288331444444511
Continuous Current Rating@45℃3&4 CoreA137169205237272311365421
Short Circuit Current 1sA715010020135901717021460264703434042930
Operating VoltageKV0.6/10.6/10.6/10.6/10.6/10.6/10.6/10.6/1

Note: For more than 4-cores, the current ratings may be calculated from the following formula (IN=I1/ ³√ N ), I1= Current rating for 1-core, N = Number of cores.

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors35404550556065707580
Rating Factor1.11.051.00.940.880.820.740.670.580.47

Mechanical and Thermal Properties

  • Bending Radius :20×OD (during installation); 12×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight

Construction No. of cores×Crosssection

(mm²)

Nominal InsulationThickness

mm

Nominal Diameter Over Bedding

mm

Nominal Diameter Over Sheath1

mm

Nominal Overall

Diameter

mm

Nominal Weight

kg/km

1×501.41518.547.9±23045
1×701.416.520.549.9±23465
1×951.618.52353.3±23990
1×1201.620.52555.3±24473
1×1501.8232757.3±24988
1×18522529.560.3±25649
1×2402.22832.569.2±27403
1×3002.430.535.571.2±28400
2×1.51101342.5±21985
2×2.511114.544.0±22184
3×1.5110.51444.0±22247
3×2.5111.51544.5±22310
3×411316.545.0±22520
3×61141847.0±22730
3×16118.52352.4±23675
3×351.22529.559.9±25082
3×701.4333974.4±28558
3×1201.6414883.9±211865
3×1501.84654.591.3±213965
4×2.5112.516.546.8±22415
4×6115.519.550.3±23014
4×16120.52555.5±24022
7×1.511417.546.5±22678
12×1.5118.522.552.0±23297
27×1.5126.53166.5±25324
7×2.51151948.0±22898
12×2.5120.524.554.0±23675