Loading...

Water Blocked S11 RU(i) 250 V

Water Blocked S11 RU(i) 250 V

Applications

These unarmoured cables are partially water blocked, flame retardant, low smoke and halogen-free, and used for instrumentation, communication, control, and alarm systems.

Standards

IEC 60092-376IEC 60092-351
IEC 60092-359IEC 60332-1
IEC 60332-3-22IEC 60754-1,2
IEC 61034-1,2NEK 606:2004
VG 95218 part 29

 

Water Blocked S11 RU(i) 250 V

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2.
Insulation: Halogen-free EPR compound.
Twinning: Colour-coded cores twisted together.
Filler: Water blocking fillers, if required.
Individual Shielding: Each pair/triples are screened by copper-backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.
Filler: Water blocking fillers, if required.
Water Blocking Elements: Water blocking tape and strings for providing longitudinal
water tightness.
Inner Sheath: Halogen-free thermosetting compound, SHF2, colored grey (blue for intrinsically safe).
Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.

Electrical Characteristics

Nominal Cross Section Areamm²0.751.01.52.5
Nominal Conductor Diametermm1.11.31.62.0
Maximum Resistant@20℃Ω/km26.319.312.98.02
Mutual CapacitancenF/km90100110120
Nominal Inductance@1KHzMH/km0.6860.6490.6370.598
Maximum L/R@1KHzμH/Ω20253550
Operating VoltageV250250250250

Mechanical and Thermal Properties

  • Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight

Construction

No. of elements×No. of cores in element×Cross section

(mm²)

Nominal Insulation Thickness

mm

Nominal Inner Sheath Thickness

mm

Nominal Outer Sheath Thickness mmNominal

Overall Diameter

mm

Nominal Weight

kg/km

1×2×0.750.6119.6±2100
2×2×0.750.61.1111.7±2189
4×2×0.750.61.2114.1±2268
7×2×0.750.61.3116.4±2399
8×2×0.750.61.3117.6±2446
12×2×0.750.61.5121.0±2641
16×2×0.750.61.5123.0±2824
19×2×0.750.61.6124.4±2940
24×2×0.750.61.7127.6±21192
32×2×0.750.61.8130.4±21512
1×3×0.750.61110.0±2116
2×3×0.750.61.2113.0±2189
3×3×0.750.61.2114.7±2278
4×3×0.750.61.2115.8±2341
7×3×0.750.61.4118.7±2525
8×3×0.750.61.4120.0±2567
12×3×0.750.61.6124.2±2856
16×3×0.750.61.6126.7±21097
19×3×0.750.61.7128.2±21265
24×3×0.750.61.9132.5±21622
1×2×1.00.61110.1±2116
2×2×1.00.61.1112.4±2226
4×2×1.00.61.2114.9±2326
7×2×1.00.61.4117.5±2499
8×2×1.00.61.4119.0±2567
12×2×1.00.61.5122.5±2798
16×2×1.00.61.5124.9±21045
19×2×1.00.61.7126.1±21192
24×2×1.00.61.8129.8±21523
32×2×1.00.61.9132.8±21943
1×3×1.00.61110.5±2131
3×3×1.00.61.3115.4±2336
4×3×1.00.61.3116.8±2415
7×3×1.00.61.5119.9±2646
12×3×1.00.61.6125.7±21040
16×3×1.00.61.7128.5±21360
19×3×1.00.61.8130.0±21549
24×3×1.00.62134.6±21995
1×2×1.50.71111.1±2147
2×2×1.50.71.2113.7±2294
4×2×1.50.71.3116.9±2431
7×2×1.50.71.5120.0±2667
8×2×1.50.71.5121.7±2756
12×2×1.50.71.6125.8±21066
16×2×1.50.71.6128.6±21397
19×2×1.50.71.9130.3±21601
24×2×1.50.72134.6±22042
32×2×1.50.72.2138.1±22599
1×3×1.50.71111.5±2168
2×3×1.50.71.3116.0±2299
3×3×1.50.71.3117.5±2446
4×3×1.50.71.3119.0±2551
7×3×1.50.71.6122.9±2872
8×3×1.50.71.6124.5±2945
12×3×1.50.71.8129.6±21407
16×3×1.50.71.9133.1±21859
19×3×1.50.72134.8±22121
24×3×1.50.72.2140.4±22741
1×2×2.50.71111.8±2184
1×3×2.50.71.2112.4±2215
For the best cable price, please feel free to leave your requirement, We will reply to you in 12 hours.
Thank you for your message. We will contact you within 6 hours!
There was an error trying to send your message. Please try again later.

MRE-M2X(St)H 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened Fire Resistant Instrumentation & Control Cables(Multipair/Multitriple)

Go to Top