Applications

These cables are flame retardant, low smoke and halogen-free, used for living, quarter and office areas.

Standards

IEC 60092-376IEC 60092-351
IEC 60092-359IEC 60332-1
IEC 60332-3-22IEC 60754-1,2
IEC 61034-1,2NEK 606:2004
VG 95218 part 29

 

Water Blocked S12 RU(c) 250 V

 

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2.
Insulation: Halogen free EPR compound.
Twinning: Colour coded cores twisted together.
Filler: Water blocking fillers, if required.
Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.
Water Blocking Elements: Water blocking tape and strings for providing longitudinal
water tightness.
Inner Sheath: Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).
Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.

Electrical Characteristics

Nominal Cross Section Areamm²0.751.01.5
Nominal Conductor Diametermm1.11.31.6
Maximum Resistant@20℃Ω/km26.319.312.9
Mutual CapacitancenF/km8090100
Nominal Inductance@1KHzMH/km0.6820.6450.632
Maximum L/R@1KHzμH/Ω202535
Operating VoltageV250250250

Mechanical and Thermal Properties

  • Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight

Construction

No. of elements×No. of cores in element×Cross section

(mm²)

Nominal Insulation Thickness

mm

Nominal Inner Sheath Thickness

mm

Nominal Outer Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weight

kg/km

2×2×0.750.61.1111.4±2168
4×2×0.750.61.1113.5±2226
7×2×0.750.61.3115.6±2315
8×2×0.750.61.3116.7±2357
12×2×0.750.61.4119.6±2488
16×2×0.750.61.5121.7±2625
19×2×0.750.61.5122.7±2698
24×2×0.750.61.7126.1±2893
32×2×0.750.62128.7±21118
2×3×0.750.61.1113.0±2179
3×3×0.750.61.1114.1±2247
4×3×0.750.61.2115.1±2294
7×3×0.750.61.4117.7±2431
8×3×0.750.61.4119.5±2515
12×3×0.750.61.5122.6±2677
16×3×0.750.61.6125.1±2877
19×3×0.750.61.7126.3±2987
24×3×0.750.61.8130.2±21271
2×2×1.00.61.1111.9±2200
4×2×1.00.61.1114.3±2268
7×2×1.00.61.3116.7±2389
8×2×1.00.61.3117.7±2431
12×2×1.00.61.5120.9±2593
16×2×1.00.61.6123.1±2767
19×2×1.00.61.7124.5±2872
24×2×1.00.61.8127.9±21103
32×2×1.00.62.1130.7±21381
3×3×1.00.61.1114.9±2294
4×3×1.00.61.3116.0±2352
7×3×1.00.61.5118.9±2525
12×3×1.00.61.6124.1±2835
16×3×1.00.61.6126.8±21076
19×3×1.00.61.8128.3±21234
24×3×1.00.62132.4±21565
2×2×1.50.71.2113.3±2263
4×2×1.50.71.2116.1±2362
7×2×1.50.71.4119.2±2541
8×2×1.50.71.4120.4±2604
12×2×1.50.71.6124.4±2851
16×2×1.50.71.7127.0±21097
19×2×1.50.71.8128.4±21234
24×2×1.50.71.9132.7±21580
32×2×1.50.72.2135.9±21985
2×3×1.50.71.2115.5±2278
3×3×1.50.71.2116.9±2399
4×3×1.50.71.3118.3±2488
7×3×1.50.71.5121.8±2740
8×3×1.50.71.5123.5±2861
12×3×1.50.71.7128.2±21197
16×3×1.50.71.8131.4±21549
19×3×1.50.71.9132.9±21759
24×3×1.50.72.1138.2±22268